  • Manufacturer: GE Fanuc

  • Part Number: DS200TCCBG8BED

  • Condition:New with Original Package

  • Product Type: Analog Input Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE DS200TCCBG1BED Mark V Speedtronic Extended Analog I/O Board

The GE DS200TCCBG1BED, also cataloged as the DS200TCCB Extended Analog I/O Board, operates as a dedicated hardware component for signal routing, communication synchronization, and peripheral data exchange within Mark V Speedtronic platforms.

Hardware Specifications

Parameter Specification
Model DS200TCCBG1BED
Brand GE (General Electric)
Origin USA
Weight 1.2 kg
Dimensions Standard Mark V rack size (330 x 280 mm)
Operating Temp 0 to 60 deg C
Power Consumption Dependent on backplane load
Product Type Extended Analog I/O Board (TCCB)
Operating Voltage 24 VDC (from system PSU)
System Compatibility GE Mark V Speedtronic Turbine Control System
PCB Coating Normal Coating
Functional Revisions G1, Revision 1B, Revision 2E
Artwork Revision Revision D
Diagnostic Display Onboard LEDs for status and fault indication
Hardware Protection Integrated fuse protection for onboard circuits
Storage Temp -40 to +85 deg C

Deterministic Backplane Communications & Network Execution

The board manages analog I/O signal conditioning and communication timing across the Mark V backplane bus to ensure real-time data execution. Embedded logic handles channel synchronization and internal signal routing without increasing processor latency. Onboard diagnostic LEDs continuously monitor bus traffic and fuse circuit health, while hardware jumpers allow technicians to adjust communication setup, timing parameters, and signal line burdens.

Frequently Asked Questions

Q: Can the DS200TCCBG1BED board be hot-swapped while the Mark V rack is energized?

A: No. Operating personnel must completely isolate all 24 VDC system power before extracting or seating the board. Hot-swapping risks damaging sensitive backplane bus components and corrupting active analog signals.

Q: How do functional revisions impact board replacement for the DS200TCCBG1BED?

A: Hardware revisions 1B and 2E along with artwork revision D modify internal board trace layouts and firmware flash compatibility. Maintenance staff must verify that jumpers match system configuration drawings before commissioning a replacement module.

Q: What function do the integrated onboard fuses serve on this module?

A: The fuses safeguard internal distribution paths against external electrical overcurrent conditions. An illuminated diagnostic LED on the board edge signals a tripped fuse state for immediate fault location.

Field Installation Guidelines

  • Disconnect all primary power supplies feeding the Mark V card cage before beginning replacement procedures.
  • Wear an ESD grounding wrist strap attached to the cabinet ground stud to prevent electrostatic damage during module handling.
  • Verify that all onboard jumper positions match the exact configuration of the replaced board before inserting it into the rack.
  • Align the board along the card cage guide rails and seat it firmly into the backplane connector before tightening the retention hardware.