{"product_id":"ge-epscpe115-rsti-ep-industrial-programmable-automation-controllers","title":"GE EPSCPE115 RSTi-EP Industrial Programmable Automation Controllers","description":"\u003ch2\u003eGE EPSCPE115 RSTi-EP Programmable Automation Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-speed process logic and distributed control in industrial networks, the \u003cstrong\u003eGE EPSCPE115\u003c\/strong\u003e (\u003cstrong\u003eEPSCPE115\u003c\/strong\u003e Programmable Automation Controller) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEPSCPE115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail module weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCompact RSTi-EP housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard RSTi-EP backplane power load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Memory\u003c\/td\u003e\n\u003ctd\u003e1.5 MB storage capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2K bits discrete I\/O, 32K words analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Ports\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Mbps port, 1 x 3-port Ethernet switch (10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS-232 port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Ports\u003c\/td\u003e\n\u003ctd\u003e1 x USB-A 2.0 host, 1 x MicroSD card slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003ePROFINET, OPC UA, Modbus TCP\/IP, SRTP, EGD, MRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eAchilles Level 2 cybersecurity certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet and Deterministic Network Processing Features\u003c\/h3\u003e\n\u003cp\u003eThe controller's digital processing core links field devices across Profinet \/ EtherNet\/IP deterministic networks while maintaining steady packet delivery through the integrated 3-port Ethernet switch. System engineers rely on Media Redundancy Protocol (MRP) topology to prevent link failure drops without degrading backplane bus communication velocity. Internal memory structures handle up to 8 PROFINET I\/O devices, aligning high-density field data while verifying firmware flash compatibility across connected RSTi-EP expansion modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How do engineers prevent memory corruption during firmware flash compatibility updates on the EPSCPE115?\u003c\/p\u003e\n\u003cp\u003eA: Stop controller logic execution, back up user programs to a MicroSD card, and disconnect field PROFINET devices before transferring the firmware update over the primary Ethernet port.\u003c\/p\u003e\n\u003cp\u003eQ: How does Media Redundancy Protocol (MRP) prevent network dropouts in ring topologies?\u003c\/p\u003e\n\u003cp\u003eA: MRP automatically redirects deterministic industrial network traffic around broken cable segments in less than 200 ms, keeping the OPC UA server and Modbus TCP links operational without losing controller I\/O scan state.\u003c\/p\u003e\n\u003cp\u003eQ: What grounding precautions must technicians follow when using the RS-232 serial interface?\u003c\/p\u003e\n\u003cp\u003eA: Connect the serial cable shield directly to the cabinet earth ground bus while keeping signal lines isolated from high-voltage AC motor drives to protect internal serial transceiver chips.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eDIN-Rail Mounting and Structural Lock: Position the upper notch of the controller module onto the 35 mm DIN rail. Press the lower housing firm against the rail until the spring-loaded metal clip snaps into position to prevent lateral shifting under heavy vibration.\u003c\/p\u003e\n\u003cp\u003eEthernet Port Cable Shield Routing: Use double-shielded CAT6 cable runs for all 10\/100 Mbps Ethernet connections. Ground cable braid shields at the cabinet entrance plate rather than relying on port housing connections to avoid ground potential loops across network nodes.\u003c\/p\u003e\n\u003cp\u003ePower and Auxiliary Wiring Separation: Run incoming 24 VDC auxiliary power lines through separate wire trunks isolated from high-frequency AC output wiring. Secure all field wire bundles using panel raceways to maintain clean physical separation.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872625655907,"sku":"EPSCPE115","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/393.1_0d662a23-d980-4cd8-a947-77c32ebd2715.jpg?v=1764906096","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-epscpe115-rsti-ep-industrial-programmable-automation-controllers","provider":"AutoControl Global","version":"1.0","type":"link"}