{"product_id":"ge-fanuc-ic200mdl240-versamax-discrete-input-module","title":"GE Fanuc IC200MDL240 VersaMax Discrete Input Module","description":"\u003ch2\u003eGE Fanuc IC200MDL240 VersaMax I\/O Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL240\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL240\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for binary AC signal acquisition within VersaMax I\/O and Control System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e110 mA maximum (from 5 VDC backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Discrete Inputs (2 groups of 8 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e70 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA at 120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Response Time\u003c\/td\u003e\n\u003ctd\u003e1 cycle (ON) \/ 2 cycles (OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC for 1 minute (Group-to-Group \u0026amp; Frame-to-Ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Requirement\u003c\/td\u003e\n\u003ctd\u003eNone required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane LED Indicator\u003c\/td\u003e\n\u003ctd\u003e1 OK LED for backplane power presence\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel LED Indicators\u003c\/td\u003e\n\u003ctd\u003e16 individually numbered LEDs for channel ON\/OFF status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Signal Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe module utilizes an internal backplane bus interface that draws a maximum current of 110 mA to drive optical isolation circuitry and local logic processing. Internal optocouplers establish galvanic isolation rated at 1500 VAC for 1 minute between independent channel groups and frame ground circuits. This configuration limits cross-talk propagation and suppresses common-mode surge voltage transients across adjacent field wiring terminals.\u003c\/p\u003e\n\u003cp\u003eThe module interfaces with the backplane bus via a compatible VersaMax carrier base (IC200CHS series). Firmware execution relies on direct backplane bus communication velocity to pass 16-point discrete image tables to the CPU during standard I\/O scan execution cycles without requiring external field power supplies for internal module operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200MDL240 require an external power supply to power its internal logic circuitry?\u003c\/p\u003e\n\u003cp\u003eA: No, the module draws its operating power directly from the 5 VDC VersaMax backplane bus through the carrier base, requiring a maximum backplane current allocation of 110 mA.\u003c\/p\u003e\n\u003cp\u003eQ: How are the input channels electrically isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: The 16 input channels are arranged into 2 isolated groups of 8 channels each, providing group-to-group and group-to-frame ground optical isolation rated up to 1500 VAC for 1 minute or 250 VAC continuous.\u003c\/p\u003e\n\u003cp\u003eQ: Can this discrete input module be installed while the backplane power is active?\u003c\/p\u003e\n\u003cp\u003eA: Field technicians must remove backplane power prior to inserting or removing the module from its IC200CHS carrier base to avoid logic errors or connector pin degradation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the targeted VersaMax rack and verify that no field-side voltage exists on the field wiring terminals before beginning installation procedures.\u003c\/li\u003e\n\u003cli\u003eAlign the IC200MDL240 module housing with the mounting guides of the designated IC200CHS carrier base.\u003c\/li\u003e\n\u003cli\u003ePress the module firmly onto the carrier connector interface until the mechanical latching tabs fully engage with the housing assembly.\u003c\/li\u003e\n\u003cli\u003eWire the 120 VAC field inputs to the carrier terminal block, keeping channel group commons strictly separated to maintain group-to-group isolation boundaries.\u003c\/li\u003e\n\u003cli\u003eSecure all field wiring harnesses within cabinet cable trays, ensuring signal lines run perpendicular to heavy inductive AC motor loads to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eReapply backplane system power and verify that the module backplane OK LED illuminates solid green before initiating functional signal testing.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44539281801315,"sku":"IC200MDL240","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/166._2319b5ce-4716-4674-9dc0-9270d133bb42.jpg?v=1788241402","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic200mdl240-versamax-discrete-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}