GE Fanuc IC200MDL241J VersaMax 16 Point Sourcing Output Module
Manufacturer: GE Fanuc
-
Part Number: IC200MDL241J
Condition:New with Original Package
Product Type: Digital Output Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC200MDL241J VersaMax Discrete Output Module
The GE Fanuc IC200MDL241J, also cataloged as the IC200MDL241 Discrete Output Module, operates as a dedicated hardware component for converting CPU logic signals into 24 VDC sourcing outputs within VersaMax platforms.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC200MDL241J |
| Brand | GE Fanuc |
| Origin | Refer to device label |
| Weight | 0.28 kg (0.63 lbs) |
| Dimensions | 110 mm x 66.8 mm x 50.0 mm |
| Operating Temp | 0 deg C to +60 deg C |
| Power Consumption | 100 mA max at 5 VDC (Backplane) |
| Output Channels | 16 discrete positive logic (sourcing) outputs |
| Operating Voltage | 10.2-30 VDC (Nominal 24 VDC) |
| Max Current | 0.5 A max per point (2 A max per common) |
| Isolation | 250 VAC continuous, 1500 VAC for 1 min |
| Response Time | Less than 0.5 ms (ON/OFF) |
| Diagnostic LEDs | 16 channel status LEDs, 1 system OK LED |
Backplane Bus Communication Velocity & I/O Density Scaling
The module routes CPU control instructions across the VersaMax serial backplane bus with minimal communication latency, executing fast signal switching under 0.5 ms. Internal optocouplers deliver point-to-point and group-to-logic galvanic isolation rated to 250 VAC continuous, preventing ground loops and voltage surges from degrading backplane bus communication velocity. Additionally, the 16-point positive logic sourcing layout scales I/O density within a compact single-carrier footprint while drawing a maximum logic current of 100 mA at 5 VDC from the backplane power supply rail.
Frequently Asked Questions
Q: What are the current rating restrictions when driving high-density field loads from a single output group?
A: Each individual point supports up to 0.5 A DC, but total combined current across channels sharing a single common line must not exceed 2.0 A to prevent thermal overload on internal trace pathways.
Q: How does the module handle inductive load turn-off transients?
A: Internal switching components feature built-in voltage clamping, but external flyback diodes should be installed directly across inductive DC loads like solenoids to absorb inductive surges and safeguard field terminals.
Field Installation Guidelines
Mount the VersaMax I/O carrier securely onto a standard 35 mm DIN rail or directly to the enclosure panel using M4 mounting hardware. Ensure the 24 VDC external loop power source is turned off before seating the module onto its carrier connector. Route field output cables away from high-voltage AC lines to prevent capacitive interference. Connect field signal wires to the screw terminals on the carrier, ensuring positive logic sourcing polarity matches the field device ground configuration, and connect the central cabinet earth bus directly to the carrier grounding tab.