{"product_id":"ge-fanuc-ic200mdl650l-versamax-32-point-24-vdc-discrete-input-module","title":"GE Fanuc IC200MDL650L VersaMax 32-Point 24 VDC Discrete Input Module","description":"\u003ch2\u003eGE Fanuc IC200MDL650L VersaMax Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL650L\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL650\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for digital signal acquisition within VersaMax I\/O systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL650L (IC200MDL650)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 50 mA max backplane current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e32 points (4 groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Nominal\u003c\/td\u003e\n\u003ctd\u003e24 VDC positive logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e15 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 to 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e2.0 to 5.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Current\u003c\/td\u003e\n\u003ctd\u003e0.0 to 0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e10 kOhm max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.5 ms default (configurable 0 ms, 1 ms, 7 ms filter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min (inputs to backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e32 green point LEDs, 1 green backplane power OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module transfers 32 discrete input state signals to the central CPU through high-density backplane bus communication velocity channels. Integrated optical isolation shields internal logic circuits and system processing units from high-voltage field spikes up to 1500 VAC. Dedicated hardware registers map input states directly into system memory each scan cycle without incurring field-side polling delay. Furthermore, individual channel response filters attenuate contact bounce and high-frequency line noise, ensuring deterministic signal updating across expandable I\/O density carrier tracks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does replacing an IC200MDL650L module require resetting system power to the VersaMax carrier backplane?\u003c\/p\u003e\n\u003cp\u003eA: No, field installation procedure permits hot-insertion and hot-removal of the module on active VersaMax I\/O carriers while maintaining logic backplane continuity.\u003c\/p\u003e\n\u003cp\u003eQ: How does input response filtering function across individual channel groups?\u003c\/p\u003e\n\u003cp\u003eA: Software configuration updates filter constant registers to selectable 0 ms, 1 ms, or 7 ms intervals, suppressing noise artifacts before signal states commit to the backplane memory matrix.\u003c\/p\u003e\n\u003cp\u003eQ: Can channels on the IC200MDL650L be wired for negative logic sensor configurations?\u003c\/p\u003e\n\u003cp\u003eA: Standard IC200MDL650 hardware targets positive logic, while full native negative logic sourcing configurations require hardware revision IC200MDL650C or higher.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the IC200MDL650L module directly onto its assigned VersaMax I\/O carrier interface rail until mechanical latches engage fully. Route field input conductors to individual terminal block pins, ensuring each group of 8 input channels connects through its designated common return rail. Maintain direct single-point grounding from the carrier backplane terminal bar to the enclosure earth ground bus using 14 AWG copper wire. Separate signal conductors from high-voltage power lines inside panel trunking by at least 100 mm to suppress electro-magnetic interference.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44524519620707,"sku":"IC200MDL650L","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/201._16d1d9b9-68d0-4579-a811-a95264ebcdaa.jpg?v=1787896608","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic200mdl650l-versamax-32-point-24-vdc-discrete-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}