{"product_id":"ge-fanuc-ic200mdl750e-versamax-32-point-output-module","title":"GE Fanuc IC200MDL750E VersaMax 32 Point Output Module","description":"\u003ch2\u003eGE Fanuc IC200MDL750E VersaMax Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC200MDL750E\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200MDL750\u003c\/strong\u003e Discrete Output Module, operates as a dedicated hardware component for high-density DC switching within VersaMax platforms. The module manages 32 discrete output channels organized into two isolated groups of 16 channels, providing direct field actuation for solenoids, relays, and indicators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL750E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax carrier dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +30 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA maximum @ 5 VDC (backplane current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e32 sourcing DC channels (2 groups of 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e12 \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A for 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON \/ OFF Switching Response\u003c\/td\u003e\n\u003ctd\u003eON: 0.2 ms \/ OFF: 1.0 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Fuses\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd\u003eIndividual channel LEDs, OK LED, FLD PWR LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Integration\u003c\/h3\u003e\n\u003cp\u003eThe module coordinates output register state transitions across the VersaMax backplane bus with minimal timing jitter. Fast switching response times of 0.2 ms for ON transitions and 1.0 ms for OFF transitions allow execution of high-speed digital actuation cycles. System logic updates maintain bus communication velocity across the backplane, and firmware flash compatibility ensures predictable I\/O density scaling and diagnostic status reporting during continuous operational scans.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What external protection is required since the module lacks internal fuses?\u003c\/p\u003e\n\u003cp\u003eA: Because no internal fuses exist on the module, branch circuit protection or external fast-acting field fuses must be installed on the 10.2–30 VDC field supply lines to prevent channel damage from overcurrent faults.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum allowable inrush current per channel?\u003c\/p\u003e\n\u003cp\u003eA: Each output channel handles a maximum peak inrush current of 2.0 A for a duration of up to 100 ms.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical isolation managed between internal logic and external field circuits?\u003c\/p\u003e\n\u003cp\u003eA: The hardware incorporates optical isolation rated for 250 VAC continuous continuous duty and tested up to 1500 VAC for 1 minute between backplane logic and field terminals.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module onto a standard 35 mm DIN rail or panel baseplate using compatible VersaMax I\/O carrier bases.\u003c\/li\u003e\n\u003cli\u003eConnect external 12\/24 VDC power across both isolated channel groups, verifying correct supply polarity before energizing field loops.\u003c\/li\u003e\n\u003cli\u003eRoute output signal cabling away from heavy AC power lines to reduce inductive cross-coupling and high-frequency noise interference.\u003c\/li\u003e\n\u003cli\u003eConnect cable shields to a dedicated protective earth ground bar near the enclosure entrance to maintain signal integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44453366399075,"sku":"IC200MDL750A","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/471_6e8b0234-8572-4c17-995d-696f5fc810a9.jpg?v=1786087135","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic200mdl750e-versamax-32-point-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}