GE Fanuc IC200UDR164 VersaMax Micro Controller
Manufacturer: GE Fanuc
-
Part Number: IC200UDR164
Condition:New with Original Package
Product Type: Micro Controllers
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC200UDR164 VersaMax Micro Controller
Configured for high-density discrete switching and logic processing in localized automation networks, the GE Fanuc IC200UDR164 (IC200UDR164 Micro PLC) provides direct physical/electrical execution.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC200UDR164 |
| Brand | GE Fanuc / Emerson |
| Origin | USA |
| Weight | 2.00 lbs (0.91 kg) |
| Dimensions | Standard DIN-rail unit profile |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 30 VA |
| Main Input Voltage | 100-240 VAC (50-60 Hz) |
| Inrush Current | 40 A at 265 VAC, 30 A at 200 VAC |
| Hold-up Time | 10 ms at 85-100 VAC, 20 ms at 100-265 VAC |
| Total Integrated I/O | 64 Points (40 Inputs, 24 Outputs maximum footprint configuration) |
| DC Input Channels | 16 DC inputs, 24 VDC nominal (0-30 VDC range) |
| Input Logic & Thresholds | Positive/Negative logic; ON >= 15 VDC, OFF <= 5 VDC |
| Input Response Time | Configurable 0.5 to 20 ms |
| Relay Output Channels | 12 relay outputs, SPST Form A (Normally Open) |
| Maximum Switching Load | 2 A per point (5-30 VDC / 5-250 VAC), Resistive |
| Mechanical / Electrical Life | 20,000,000 mechanical ops; 200,000 electrical ops at rated load |
| Auxiliary Sensor Supply | 24 VDC, 200 mA max output |
| Isolation Rating | 1500 V RMS field-to-logic; 500 V RMS channel group-to-group |
| Hazardous Location Rating | Class I, Div 2, Groups A-D |
Industrial Control & Deterministic Execution Features
The IC200UDR164 utilizes an integrated backplane bus architecture designed to execute scan cycles with strict deterministic timing. I/O density scaling allows seamless addition of local VersaMax Micro expansion modules without compromising logic execution speed. Field-to-logic galvanic isolation prevents ground loop currents from affecting CPU operation, while onboard firmware flash compatibility ensures stable instruction execution under fluctuating electrical noise profiles.
Frequently Asked Questions
Q: What are the restrictions regarding relay output switching frequency on the IC200UDR164?
A: Mechanical relay contacts exhibit an operational lifespan limit of approximately 200,000 cycles under full 2 A resistive load. High-frequency duty cycles must be cushioned using external interposition solid-state relays to prevent early contact erosion.
Q: Can field sensors be powered directly from the controller hardware?
A: Yes. The unit provides an auxiliary 24 VDC terminal output rated up to 200 mA. If the total sensor current draw exceeds 200 mA, an external dedicated power supply must be connected to the field device loop.
Field Installation Guidelines
Mount the unit securely on a standard 35 mm DIN rail or directly to a backpanel using rigid fasteners. Verify that the line supply (100-240 VAC) is completely isolated before terminating power cables. Maintain a minimum of 50 mm vertical clearance around ventilation slots to ensure heat dissipation. Wire field I/O using copper conductors rated for at least 75 deg C, ensuring power lines are physically segregated from signal lines to limit inductive cross-talk. Ground the system enclosure to the central protective earth (PE) bus through a low-impedance conductor.