{"product_id":"ge-fanuc-ic200udr164-versamax-micro-controller","title":"GE Fanuc IC200UDR164 VersaMax Micro Controller","description":"\u003ch2\u003eGE Fanuc IC200UDR164 VersaMax Micro Controller\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-density discrete switching and logic processing in localized automation networks, the \u003cstrong\u003eGE Fanuc IC200UDR164\u003c\/strong\u003e (\u003cstrong\u003eIC200UDR164\u003c\/strong\u003e Micro PLC) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable style=\"width: 100%; height: 685.782px;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003cth style=\"width: 32.8218%; height: 19.5938px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth style=\"width: 62.4724%; height: 19.5938px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003eIC200UDR164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003e2.00 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003eStandard DIN-rail unit profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e30 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eMain Input Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e100-240 VAC (50-60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 19.5938px;\"\u003eInrush Current\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 19.5938px;\"\u003e40 A at 265 VAC, 30 A at 200 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eHold-up Time\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e10 ms at 85-100 VAC, 20 ms at 100-265 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eTotal Integrated I\/O\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e64 Points (40 Inputs, 24 Outputs maximum footprint configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eDC Input Channels\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e16 DC inputs, 24 VDC nominal (0-30 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eInput Logic \u0026amp; Thresholds\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003ePositive\/Negative logic; ON \u0026gt;= 15 VDC, OFF \u0026lt;= 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eInput Response Time\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003eConfigurable 0.5 to 20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eRelay Output Channels\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e12 relay outputs, SPST Form A (Normally Open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eMaximum Switching Load\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e2 A per point (5-30 VDC \/ 5-250 VAC), Resistive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 58.7812px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 58.7812px;\"\u003eMechanical \/ Electrical Life\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 58.7812px;\"\u003e20,000,000 mechanical ops; 200,000 electrical ops at rated load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eAuxiliary Sensor Supply\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e24 VDC, 200 mA max output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003e1500 V RMS field-to-logic; 500 V RMS channel group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 39.1875px;\"\u003e\n\u003ctd style=\"width: 32.8218%; height: 39.1875px;\"\u003eHazardous Location Rating\u003c\/td\u003e\n\u003ctd style=\"width: 62.4724%; height: 39.1875px;\"\u003eClass I, Div 2, Groups A-D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Deterministic Execution Features\u003c\/h3\u003e\n\u003cp\u003eThe IC200UDR164 utilizes an integrated backplane bus architecture designed to execute scan cycles with strict deterministic timing. I\/O density scaling allows seamless addition of local VersaMax Micro expansion modules without compromising logic execution speed. Field-to-logic galvanic isolation prevents ground loop currents from affecting CPU operation, while onboard firmware flash compatibility ensures stable instruction execution under fluctuating electrical noise profiles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the restrictions regarding relay output switching frequency on the IC200UDR164?\u003c\/p\u003e\n\u003cp\u003eA: Mechanical relay contacts exhibit an operational lifespan limit of approximately 200,000 cycles under full 2 A resistive load. High-frequency duty cycles must be cushioned using external interposition solid-state relays to prevent early contact erosion.\u003c\/p\u003e\n\u003cp\u003eQ: Can field sensors be powered directly from the controller hardware?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The unit provides an auxiliary 24 VDC terminal output rated up to 200 mA. If the total sensor current draw exceeds 200 mA, an external dedicated power supply must be connected to the field device loop.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit securely on a standard 35 mm DIN rail or directly to a backpanel using rigid fasteners. Verify that the line supply (100-240 VAC) is completely isolated before terminating power cables. Maintain a minimum of 50 mm vertical clearance around ventilation slots to ensure heat dissipation. Wire field I\/O using copper conductors rated for at least 75 deg C, ensuring power lines are physically segregated from signal lines to limit inductive cross-talk. Ground the system enclosure to the central protective earth (PE) bus through a low-impedance conductor.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44536616353891,"sku":"IC200UDR164","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/209.1_63ce9a9a-6323-45f2-8482-759076b4d806.jpg?v=1788157061","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic200udr164-versamax-micro-controller","provider":"AutoControl Global","version":"1.0","type":"link"}