{"product_id":"ge-fanuc-ic660bbd110-genius-i-o-discrete-input-block","title":"GE Fanuc IC660BBD110 Genius I\/O Discrete Input Block","description":"\u003ch2\u003eGE IC660BBD110 Genius I\/O Discrete Input Block\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC660BBD110\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660BBD110\u003c\/strong\u003e Discrete Input Block, operates as a dedicated hardware component for direct AC digital signal monitoring and fault detection within Genius I\/O serial network architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660BBD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.81 lbs (1.73 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.83 x 3.34 x 3.91 inches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (32 to 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e8 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e93-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 discrete input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Block Current\u003c\/td\u003e\n\u003ctd\u003e80 mA max block current plus 200 mA max input circuit current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgrammable Threshold\u003c\/td\u003e\n\u003ctd\u003e25% to 85% for off\/on state detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Input Filter\u003c\/td\u003e\n\u003ctd\u003e10 to 100 ms in 10 ms increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Diagnostics\u003c\/td\u003e\n\u003ctd\u003eOpen wire, short circuit detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e1500 V input-to-ground or serial bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Interface\u003c\/td\u003e\n\u003ctd\u003eGenius RS-485 serial bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eLEDs for Unit OK and I\/O Enabled status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe IC660BBD110 relies on the deterministic Genius RS-485 serial bus protocol to handle discrete field sensor telemetry across legacy Series 90-30 and 90-70 PLC platforms. System integration relies on high-density I\/O scanning cycles where each of the 16 discrete AC circuits processes raw voltage inputs through programmable digital filters adjustable from 10 ms to 100 ms. Dynamic firmware compatibility inside the unit enforces channel-to-bus isolation at 1500 V, preserving backplane bus communication velocity and preventing field voltage spikes from degrading serial data integrity across the distributed network topology.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the block handle shorted and open wire diagnostic conditions?\u003c\/p\u003e\n\u003cp\u003eA: The onboard circuitry evaluates loop integrity continuously using fixed 10% to 90% thresholds to detect shorted field wiring, while asserting open circuit diagnostic flags when current drops below configured operating levels.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input response time be altered to prevent contact chatter?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Users can configure the internal digital input filter time from 10 ms to 100 ms in 10 ms increments via the Genius serial bus interface or a handheld monitor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the unit vertically on a standard enclosure backplate to optimize airflow through the passive cooling vents. Run field wiring for the 115 VAC input circuits in separate wireways away from low-voltage communication cables to prevent inductive noise coupling. Ensure the Genius RS-485 serial bus shield connects securely to the local chassis ground at only one point in the cable segment to maintain effective noise immunity and avoid ground loop potentials.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44517938233443,"sku":"IC660BBD110","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/163_63863270-aebe-4233-a41f-58ac39059c8d.jpg?v=1787731449","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic660bbd110-genius-i-o-discrete-input-block","provider":"AutoControl Global","version":"1.0","type":"link"}