{"product_id":"ge-fanuc-ic670mdl240-field-control-input-module","title":"GE Fanuc IC670MDL240 Field Control Input Module","description":"\u003ch2\u003eGE Fanuc IC670MDL240 Field Control Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for 120 VAC discrete signal acquisition in Field Control platforms, the \u003cstrong\u003eGE Fanuc IC670MDL240J\u003c\/strong\u003e (\u003cstrong\u003eIC670MDL240\u003c\/strong\u003e Discrete Input Module) provides direct physical signal processing across 16 AC input channels. It converts incoming AC field signals into logic states for transmission across the Bus Interface Unit backplane interface.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Revision \u0026amp; Status Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL240\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Field Control 16-Point 120 VAC Discrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL240J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific Revision J Hardware Variant Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL240J (Base Model: IC670MDL240)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control Module Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (Storage: -40 deg C to +85 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e77 mA maximum draw from Bus Interface Unit backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (Nominal 115 VAC, operating range: 0-132 VAC, 47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 discrete channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Input Current\u003c\/td\u003e\n\u003ctd\u003e8.2 mA typical per point at 120 VAC (up to 15 mA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e70 VAC to 132 VAC (On-state current: 4.0-10 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 VAC to 20 VAC (Off-state current: 0-2.5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e14.6 k-ohm @ 60 Hz (17.6 k-ohm @ 50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-On Response Time\u003c\/td\u003e\n\u003ctd\u003e12 ms typical (20 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-Off Response Time\u003c\/td\u003e\n\u003ctd\u003e25 ms typical (40 ms maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (1500 VAC for 1 min group-to-group\/logic\/frame ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC670MDL240J optimizes system performance by processing 16 AC discrete channels through an internal opto-isolation architecture that prevents high-voltage transients from affecting local logic circuits. RC noise filtering suppression minimizes contact bounce effects, allowing precise state updates without compromising backplane bus communication velocity across local subracks. Firmware flash compatibility across parent CPU units ensures stable address decoding and scan execution over the Bus Interface Unit connection.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How are the input channels organized for power isolation on the IC670MDL240J?\u003c\/p\u003e\n\u003cp\u003eA: The 16 input channels are arranged to support isolation between field groups, allowing separate external 120 VAC power sources to feed independent channel banks.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current load drawn by the IC670MDL240J from the local Bus Interface Unit?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 77 mA from the internal 5 VDC logic power supply provided by the Bus Interface Unit.\u003c\/p\u003e\n\u003cp\u003eQ: What are the typical and maximum turn-off response times for field signals on this module?\u003c\/p\u003e\n\u003cp\u003eA: The off-response time is 25 ms typical, with a maximum limit of 40 ms to account for AC sine wave zero-crossing and internal filter discharge.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize all primary field power supplies and Bus Interface Unit power connections before installing the module into its terminal block.\u003c\/li\u003e\n\u003cli\u003eWire field signals using AWG #14 to #22 conductors, ensuring screw terminals are secured properly to prevent loose high-voltage connections.\u003c\/li\u003e\n\u003cli\u003eMaintain separate conduit runs for 120 VAC field power wiring and low-voltage logic cabling to avoid inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003eVerify that external 120 VAC field power supplies operate within the 47 to 63 Hz frequency range prior to commissioning.\u003c\/li\u003e\n\u003cli\u003eMonitor channel LED status lights during startup to confirm proper signal transitions and power rail integrity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44511362809955,"sku":"IC670MDL240","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/148._a694247d-fd4b-4e69-9c81-899c822932a8.jpg?v=1787642631","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic670mdl240-field-control-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}