{"product_id":"ge-fanuc-ic670mdl240j-field-control-input-module","title":"GE Fanuc IC670MDL240J Field Control Input Module","description":"\u003ch2\u003eGE Fanuc IC670MDL240J Field Control Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC670MDL240J\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC670MDL240\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 120 VAC discrete signal acquisition within Field Control distributed I\/O systems. It interfaces physical input signals from field switches and sensors directly to the local Bus Interface Unit for logic execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003ePart Number \/ Identifier\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eHardware Revision \u0026amp; Status Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL240\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Field Control 16-Point 120 VAC Discrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670MDL240J\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific Revision J Hardware Variant Identifier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL240J (Base Model: IC670MDL240)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.48 kg (1.06 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Control Module Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C (Storage: -40 deg C to +85 deg C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e77 mA maximum draw from BIU power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC (Nominal 115 VAC, operating range: 0-132 VAC, 47-63 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 discrete AC input points (divided into two isolated groups of 8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e70 VAC to 132 VAC (74-132 VAC nominal range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOff-State Voltage\u003c\/td\u003e\n\u003ctd\u003e0 VAC to 20 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e8.2 mA typical per point at 120 VAC (up to 15 mA max per point)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Current\u003c\/td\u003e\n\u003ctd\u003e4.0 mA to 15 mA (Off-state current: 0 mA to 2.5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e~14.6 k-ohm @ 60 Hz (~17.6 k-ohm @ 50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eOn: 12 ms typ \/ 20 ms max; Off: 25 ms typ \/ 40 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous (1500 VAC for 1 min group-to-group\/logic\/frame ground)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC670MDL240J expands I\/O density scaling by integrating 16 isolated AC input points within a compact DIN-rail footprint. Channel opto-isolation circuitry segregates high-voltage AC field transients from internal system logic, preventing electrical noise transmission to the host backplane. This arrangement preserves deterministic backplane bus communication velocity across local expansion racks while maintaining firmware flash compatibility with target PACSystems RX3i and Series 90-30 controllers over the Bus Interface Unit bridge.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is field power isolated across the channels on the IC670MDL240J?\u003c\/p\u003e\n\u003cp\u003eA: The module splits 16 input channels into two distinct groups of 8 points, allowing each bank to run on an independent external 120 VAC power source for complete phase or group isolation.\u003c\/p\u003e\n\u003cp\u003eQ: What current draw does the IC670MDL240J place on the backplane logic supply?\u003c\/p\u003e\n\u003cp\u003eA: The module draws a maximum of 77 mA directly from the 5 VDC logic supply provided by the local Bus Interface Unit.\u003c\/p\u003e\n\u003cp\u003eQ: What cable sizes does the removable terminal assembly accept?\u003c\/p\u003e\n\u003cp\u003eA: The removable screw or barrier terminal block accommodates field wiring gauges from AWG #14 down to AWG #22.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all field voltage sources and de-energize the Bus Interface Unit before inserting or replacing the module assembly.\u003c\/li\u003e\n\u003cli\u003eConnect independent 120 VAC power supplies to group 1 (points 1-8) and group 2 (points 9-16) when inter-group electrical isolation is required.\u003c\/li\u003e\n\u003cli\u003eSecure field wiring into the removable terminal block using AWG #14 to #22 conductors, ensuring terminal screws are torqued to specification.\u003c\/li\u003e\n\u003cli\u003eSeparate 120 VAC discrete signal cabling from sensitive DC communication wires to mitigate inductive voltage coupling.\u003c\/li\u003e\n\u003cli\u003eCheck front-panel LED indicators during commissioning to verify power delivery and channel logic status.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44511547752547,"sku":"IC670MDL240J","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/151._350aa86f-23fb-4822-8ad2-0e8e04d892b7.jpg?v=1787643834","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic670mdl240j-field-control-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}