GE Fanuc IC670PBI001-BD Field Control Profibus-DP BIU
GE Fanuc IC670PBI001-BD Field Control Profibus-DP BIU
GE Fanuc IC670PBI001-BD Field Control Profibus-DP BIU
/ 3

GE Fanuc IC670PBI001-BD Field Control Profibus-DP BIU

  • Manufacturer: GE Fanuc

  • Part Number: IC670PBI001

  • Condition:New with Original Package

  • Product Type: Bus Interface Units

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE Fanuc IC670PBI001-BD Field Control Profibus Interface Unit

The GE Fanuc IC670PBI001-BD, also cataloged as the IC670PBI001 Profibus Bus Interface Unit, operates as a dedicated hardware component for communication bridging between Profibus-DP master controllers and local Field I/O modules within GE Field Control platforms. It manages deterministic RS-485 bus traffic across the network and presents connected I/O blocks as a single unified slave node.

Suffix Breakdown & Model Matrix

Part Number / Matrix Identifier Functional Description & Revision Status
IC670PBI001 Base Field Control Profibus-DP Bus Interface Unit Hardware
IC670PBI001-BD Specific Hardware Revision Sub-series Designation

Hardware Specifications

Parameter Specification
Model IC670PBI001-BD
Brand GE Fanuc
Origin USA
Weight 0.20 kg (0 lbs 7.0 oz) / Base unit: 0.79 kg (1.75 lbs)
Dimensions 102 mm x 178 mm x 127 mm (4.0 in x 7.0 in x 5.0 in)
Operating Temp 0 deg C to 55 deg C
Power Consumption 7.7 W Input Power (Power Dissipation: 4.45 W)
Rated Input Voltage 24 VDC (Operating Voltage Range: 18-30 VDC)
System Compatibility GE Field Control / Series 90-70 PLC
Communication Ports 1x 9-pin D-sub Profibus DP, 1x 9-pin D-sub Hand-Held Programmer
Communication Velocity Auto-detecting 9.6 kbps to 12 Mbps
Max Supported Modules Up to 8 Field I/O modules per BIU
Network Addressing Manual hardware configuration via embedded DIP switches (00-32)
Tariff Code 8517620050

Deterministic Backplane Communication Velocity & Network Integrity

The IC670PBI001-BD executes deterministic communication processing to maintain consistent cycle times across the local Field I/O backplane bus. Auto-baud rate detection synchronizes fieldbus traffic up to 12 Mbps without manual timing configuration. Internal firmware flash compatibility ensures stable message conversion latencies between local I/O registers and upstream Profibus-DP network masters, while optical isolation protects internal processing logic against differential line noise over shielded twisted-pair cabling.

Frequently Asked Questions

Q: How is the network node address assigned on the IC670PBI001-BD interface unit?

A: Node addressing is configured manually on the physical module using the embedded DIP switches before powering on the station.

Q: How many Field I/O modules can a single IC670PBI001-BD interface support on a local rack?

A: A single unit manages local backplane bus traffic for up to 8 Field I/O modules, presenting them as a consolidated slave node.

Q: What transmission speeds are supported over the RS-485 Profibus connection?

A: The physical port auto-detects standard Profibus speeds including 9.6 kbps, 19.2 kbps, 93.75 kbps, 187.5 kbps, 500 kbps, 1.5 Mbps, 3 Mbps, 6 Mbps, and 12 Mbps.

Field Installation Guidelines

  • Mount the module onto the dedicated Bus Interface Unit terminal block on a secure DIN rail or enclosure backpanel before attaching field wiring.
  • Set the node address via the embedded DIP switches prior to supplying 24 VDC input power to the terminal block connections.
  • Connect Profibus network cabling using a shielded twisted-pair conductor and standard 9-pin D-sub connectors with integrated termination resistors at line ends.
  • Ensure the external 24 VDC power supply remains within the 18-30 VDC operating threshold and satisfies the 10 ms maximum holdup time requirement.
  • Verify that panel ventilation keeps the ambient operating environment within 0 deg C to 55 deg C to maintain the unit MTBF performance.