GE Fanuc IC693MDL730J 90-30 Digital Output Modules
Manufacturer: GE Fanuc
-
Part Number: IC693MDL730J
Condition:New with Original Package
Product Type: Digital Output Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC693MDL730J Series 90-30 Digital Output Module
The GE Fanuc IC693MDL730J serves as the primary IC693MDL730 Digital Output Module utilized to execute discrete ON/OFF switching signals across Series 90-30 PLC platforms. Operating on the universal backplane, the unit controls 8 discrete DC output channels in sinking configuration to drive external solenoids, relay coils, and indicator lamps in 12 to 24 VDC industrial control circuits.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC693MDL730J |
| Brand | GE Fanuc |
| Origin | United States |
| Weight | 0.30 kg |
| Dimensions | 152 x 51 x 127 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | 100 mA @ 5 VDC backplane draw (~3 W heat dissipation) |
| Base Model | IC693MDL730 |
| Output Type | Discrete Sinking Outputs |
| Channel Count | 8 points (Rated 2 A per point) / 16 points (Rated 0.5 A max per point) |
| Output Voltage Rating | 12 to 24 VDC nominal (12 to 30 VDC operating range) |
| Maximum Output Current | 2 A per point (8 A max per module) |
| Surge Current | 1 A for 10 ms |
| Isolation | 1500 VDC between field wiring and backplane logic |
| Response Time | <1 ms typical |
| Diagnostics | Channel-specific LED status indicators |
Backplane Bus Communication Velocity & I/O Density Scaling
The IC693MDL730J transfers discrete status data directly across the Series 90-30 parallel backplane, maintaining high backplane bus communication velocity during CPU scan execution. Onboard optocouplers isolate internal logic circuits from field-side voltage spikes, preventing electrical noise propagation into the rack. Compact construction enables efficient I/O density scaling by packing multi-channel DC switching capability into a single slot position.
Frequently Asked Questions
Q: Does the IC693MDL730J support hot-swapping while the Series 90-30 rack is energized?
A: No, module removal or insertion requires complete de-energization of baseplate power and field DC power to prevent backplane bus disruption or hardware damage.
Q: How does the sinking configuration of the IC693MDL730J dictate load wiring?
A: Current flows from the external positive DC supply, through the field load, into the output channel terminal, and to the common negative return line when the internal output switch closes.
Field Installation Guidelines
- Shut down baseplate power and disconnect external DC power supplies prior to inserting the module into a backplane slot.
- Secure field load wiring to the removable terminal block using proper wire gauges rated for the connected load current.
- Install flyback protection diodes across inductive loads such as DC solenoid coils to suppress voltage transients during switching.
- Connect cabinet protective earth wiring directly to the baseplate ground terminal to preserve the 1500 VDC field-to-logic galvanic isolation barrier.