{"product_id":"ge-fanuc-ic693mdl940h-series-90-30-relay-output-module","title":"GE Fanuc IC693MDL940H Series 90-30 Relay Output Module","description":"\u003ch2\u003eGE Fanuc IC693MDL940H Series 90-30 Relay Output Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete AC and DC load switching in Series 90-30 PLC platforms, the \u003cstrong\u003eGE Fanuc IC693MDL940H\u003c\/strong\u003e (\u003cstrong\u003eIC693MDL940\u003c\/strong\u003e Relay Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940H (IC693MDL940)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 x 127 x 127 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 mA at +5 VDC (logic bus), 135 mA at +24 VDC (relay coil bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 normally open (NO) mechanical relay channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 120\/240 VAC nominal (5-30 VDC, 5-250 VAC operating range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Point\u003c\/td\u003e\n\u003ctd\u003e2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current per Common\u003c\/td\u003e\n\u003ctd\u003e4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003eUp to 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VDC field-to-logic, 500 VAC group-to-group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e15 ms max (ON to OFF \/ OFF to ON)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe internal mechanical relay coil drive circuitry interfaces with the Series 90-30 backplane, maintaining low-overhead bus processing without compromising backplane bus communication velocity during high-density I\/O update loops. Logic signals received from the main CPU drive individual relay coils via internal optical isolation barriers. Native system logic drivers deliver immediate firmware flash compatibility across all Series 90-30 CPU firmware revisions, ensuring deterministic state updating and real-time status LED indication for each contact output.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane current draw requirements for operating the IC693MDL940H module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws 7 mA from the internal +5 VDC logic bus for control logic and 135 mA from the +24 VDC bus to energize the onboard relay coils.\u003c\/p\u003e\n\u003cp\u003eQ: Are the 16 output channels on the IC693MDL940H individually isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: No, the 16 channels are organized into isolated groups sharing common terminal connections, providing 500 VAC galvanic isolation between separate terminal groups rather than channel-to-channel isolation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eIsolate all primary power sources supplying the enclosure before seating or removing the IC693MDL940H module from the Series 90-30 baseplate chassis. Align the module housing with the target slot guides and press firmly until the backplane connector latches securely into position. Wire AC or DC loads to the removable 20-pin terminal block using external fusing on each common line to protect mechanical relay contacts from overcurrent damage. Keep field output power cabling physically separated from sensitive low-level analog or communication wiring within the panel layout.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44569947078755,"sku":"IC693MDL940H","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/256_77d4a637-8a51-458c-bc41-2676a652c2ed.jpg?v=1788920301","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic693mdl940h-series-90-30-relay-output-module","provider":"AutoControl Global","version":"1.0","type":"link"}