GE Fanuc IC693MDR390C IC693MDR390 Series 90-30 Mixed I/O Module
Manufacturer: GE Fanuc
-
Part Number: IC693MDR390C
Condition:New with Original Package
Product Type: Digital Output Modules
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE Fanuc IC693MDR390C Series 90-30 Mixed I/O Module
Configured for discrete signal acquisition and load switching in Series 90-30 PLC platforms, the GE Fanuc IC693MDR390C (IC693MDR390 Mixed I/O Module) provides direct physical/electrical execution. Operating on the local backplane, the unit processes 8 discrete 24 VDC input channels while driving 8 Normally Open (N.O.) relay contact outputs to interface external field devices directly with system logic memory.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IC693MDR390C |
| Brand | GE Fanuc |
| Origin | Standard Industrial Production |
| Weight | 0.30 kg |
| Dimensions | 130 x 33 x 120 mm |
| Operating Temp | 0 to 60 deg C |
| Power Consumption | ~200 mA @ 5 VDC backplane draw (~4 W heat dissipation) |
| Base Model | IC693MDR390 |
| Input Channels | 8 discrete 24 VDC points |
| Input Voltage Range | -30 to +32 VDC |
| Input Current | 7.5 mA per channel at rated voltage |
| Output Channels | 8 Normally Open (Form A SPST) relay contact outputs |
| Output Operating Voltage | 5 to 30 VDC, 5 to 250 VAC (50/60 Hz) |
| Isolation Rating | 1500 VDC field-to-logic isolation |
Backplane Bus Communication Velocity & Firmware Flash Compatibility
The IC693MDR390C exchanges discrete status data with the CPU across the parallel backplane bus during each I/O scan sweep. Optocoupler circuits and electromechanical contact isolation prevent high-voltage switching transients on output channels from disrupting backplane bus communication velocity. Hardware firmware flash compatibility across Series 90-30 baseplate revisions guarantees stable scan timing and reliable state updates during continuous control execution.
Frequently Asked Questions
Q: Can the output contacts on the IC693MDR390C switch both AC and DC loads on adjacent channels?
A: Yes, each isolated Form A relay contact operates independently, allowing simultaneous control of AC loads up to 250 VAC and DC loads up to 30 VDC across separate output circuits.
Q: How does the IC693MDR390C indicate channel states for debugging and field validation?
A: The front panel houses individual status LEDs for both the 8 discrete input channels and the 8 relay output channels, providing real-time visual verification of logic states.
Field Installation Guidelines
- Disconnect backplane power and field voltage sources before inserting or removing the module from the Series 90-30 baseplate.
- Route high-voltage AC output wiring in separate conduit pathways away from low-voltage 24 VDC input and communication cables.
- Install external arc suppressors or RC networks across inductive loads (such as contactor coils and solenoids) to prevent contact pitting and severe electrical noise.
- Confirm that field wiring grounds attach securely to the cabinet earth bar to preserve field-to-logic galvanic isolation integrity.