GE Fanuc IC693MDR390C IC693MDR390 Series 90-30 Mixed I/O Module
GE Fanuc IC693MDR390C IC693MDR390 Series 90-30 Mixed I/O Module
GE Fanuc IC693MDR390C IC693MDR390 Series 90-30 Mixed I/O Module
/ 3

GE Fanuc IC693MDR390C IC693MDR390 Series 90-30 Mixed I/O Module

  • Manufacturer: GE Fanuc

  • Part Number: IC693MDR390C

  • Condition:New with Original Package

  • Product Type: Digital Output Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE Fanuc IC693MDR390C Series 90-30 Mixed I/O Module

Configured for discrete signal acquisition and load switching in Series 90-30 PLC platforms, the GE Fanuc IC693MDR390C (IC693MDR390 Mixed I/O Module) provides direct physical/electrical execution. Operating on the local backplane, the unit processes 8 discrete 24 VDC input channels while driving 8 Normally Open (N.O.) relay contact outputs to interface external field devices directly with system logic memory.

Hardware Specifications

Parameter Specification
Model IC693MDR390C
Brand GE Fanuc
Origin Standard Industrial Production
Weight 0.30 kg
Dimensions 130 x 33 x 120 mm
Operating Temp 0 to 60 deg C
Power Consumption ~200 mA @ 5 VDC backplane draw (~4 W heat dissipation)
Base Model IC693MDR390
Input Channels 8 discrete 24 VDC points
Input Voltage Range -30 to +32 VDC
Input Current 7.5 mA per channel at rated voltage
Output Channels 8 Normally Open (Form A SPST) relay contact outputs
Output Operating Voltage 5 to 30 VDC, 5 to 250 VAC (50/60 Hz)
Isolation Rating 1500 VDC field-to-logic isolation

Backplane Bus Communication Velocity & Firmware Flash Compatibility

The IC693MDR390C exchanges discrete status data with the CPU across the parallel backplane bus during each I/O scan sweep. Optocoupler circuits and electromechanical contact isolation prevent high-voltage switching transients on output channels from disrupting backplane bus communication velocity. Hardware firmware flash compatibility across Series 90-30 baseplate revisions guarantees stable scan timing and reliable state updates during continuous control execution.

Frequently Asked Questions

Q: Can the output contacts on the IC693MDR390C switch both AC and DC loads on adjacent channels?

A: Yes, each isolated Form A relay contact operates independently, allowing simultaneous control of AC loads up to 250 VAC and DC loads up to 30 VDC across separate output circuits.

Q: How does the IC693MDR390C indicate channel states for debugging and field validation?

A: The front panel houses individual status LEDs for both the 8 discrete input channels and the 8 relay output channels, providing real-time visual verification of logic states.

Field Installation Guidelines

  • Disconnect backplane power and field voltage sources before inserting or removing the module from the Series 90-30 baseplate.
  • Route high-voltage AC output wiring in separate conduit pathways away from low-voltage 24 VDC input and communication cables.
  • Install external arc suppressors or RC networks across inductive loads (such as contactor coils and solenoids) to prevent contact pitting and severe electrical noise.
  • Confirm that field wiring grounds attach securely to the cabinet earth bar to preserve field-to-logic galvanic isolation integrity.