{"product_id":"ge-fanuc-ic693pcm311r-programmable-coprocessor-module","title":"GE Fanuc IC693PCM311R Programmable Coprocessor Module","description":"\u003ch2\u003eGE Fanuc IC693PCM311R Series 90-30 PLC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693PCM311R\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693PCM311\u003c\/strong\u003e Programmable Coprocessor Module, operates as a dedicated hardware component for offloading math execution and string manipulation tasks within Series 90‑30 PLC networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PCM311R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 - 0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard single-slot module profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaintained via system baseplate logic power channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Memory\u003c\/td\u003e\n\u003ctd\u003e640 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e190 KB dedicated MegaBasic program space\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Ports\u003c\/td\u003e\n\u003ctd\u003e2 independent serial communication ports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseplate Compatibility\u003c\/td\u003e\n\u003ctd\u003eFits any Series 90-30 baseplate slot except slot 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe coprocessor structure coordinates directly with the main PLC CPU via localized backplane bus communication velocity parameters to process data blocks without execution delays. For complex data logging, floating-point calculations, and expansive I\/O density scaling routines, the hardware executes standalone MegaBasic code stacks matching predefined firmware flash compatibility baselines. The dual serial interfaces route external HMI and device string characters independently of deterministic network traffic, preventing communication overhead from expanding the primary PLC logic scan time.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Why is the IC693PCM311R module restricted from installation inside slot 1 of the baseplate?\u003c\/p\u003e\n\u003cp\u003eA: Slot 1 is physically and electrically wired to support the primary rack power supply unit, meaning coprocessor integration must occur inside slots 2 through 10 on the backplane bus communication velocity path.\u003c\/p\u003e\n\u003cp\u003eQ: How is memory consistency checked during local firmware flash compatibility procedures?\u003c\/p\u003e\n\u003cp\u003eA: Memory sectors are verified via hardware diagnostic routines upon boot execution, matching the 640 KB total memory allocation constraints against the running application profile.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseplate Slot Insertion:\u003c\/strong\u003e Insert the single-slot coprocessor module into any available slot between 2 and 10 on the Series 90-30 baseplate. Pivot the card until the integrated latching clips anchor fully onto the master chassis frame.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Cable Shielding Execution:\u003c\/strong\u003e Terminate the outer shields of the two serial communication port cables at the cabinet entrance ground bar. Do not route these lines in parallel with 480 VAC motor lead conductors to avoid induction errors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Port Strain Relief:\u003c\/strong\u003e Secure all RS-232\/RS-485 serial connector fasteners to ensure structural balance and prevent physical mechanical stress from degrading the onboard port pin solder connections.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872396935267,"sku":"IC693PCM311R","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/205_20eb97ba-7ac5-44e9-bd39-d317c31185b6.jpg?v=1764900459","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic693pcm311r-programmable-coprocessor-module","provider":"AutoControl Global","version":"1.0","type":"link"}