{"product_id":"ge-fanuc-ic693pwr324-series-90-30-30w-power-supply-module","title":"GE Fanuc IC693PWR324 Series 90-30 30W Power Supply Module","description":"\u003ch2\u003eGE Fanuc IC693PWR324 Series 90-30 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for internal DC voltage regulation and serial communication execution in Series 90-30 backplane racks, the \u003cstrong\u003eGE Fanuc IC693PWR324\u003c\/strong\u003e (\u003cstrong\u003eIC693PWR324\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. This slot-mounted power distribution unit converts a 100-240 VAC or 125 VDC nominal primary supply into regulated +5 VDC, +12 VDC relay, and isolated +12 VDC internal power rails while making available an integrated RS-485 serial port.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693PWR324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.86 lbs (0.39 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 Slot Size\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 W maximum input power (90 VA max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC (47-63 Hz) or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Capacity\u003c\/td\u003e\n\u003ctd\u003e30 W maximum total output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5 VDC (5.0-5.2 VDC, 30 W max), +12 VDC Relay (10.2-13.8 VDC, 5 W max), +12 VDC Isolated (10.2-13.8 VDC, 20 W max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e4 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRipple \/ Noise\u003c\/td\u003e\n\u003ctd\u003e50 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated RS-485 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBrand-Specific Hardware Architecture\u003c\/h3\u003e\n\u003cp\u003eThe backplane bus communication velocity depends directly on maintaining stable supply voltages to CPU microprocessors and digital I\/O bus interface ICs. The power supply regulates internal logic levels within a tight 5.0-5.2 VDC window while filtering field-side power surges using 1500 VAC isolation transformers. Integrated overvoltage and short-circuit protection circuits immediately interrupt backplane power if voltage parameters drift, preventing thermal degradation across the backplane bus logic structure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC693PWR324 power supply be installed in any slot on a Series 90-30 baseplate?\u003c\/p\u003e\n\u003cp\u003eA: No, field technicians must install the IC693PWR324 exclusively in the dedicated left-most power supply slot (slot 0) on the Series 90-30 baseplate to properly engage the internal backplane power buses.\u003c\/p\u003e\n\u003cp\u003eQ: What is the functional limit when utilizing the integrated RS-485 serial port on the power supply front panel?\u003c\/p\u003e\n\u003cp\u003eA: The RS-485 serial port provides physical connectivity for programming devices, operator interfaces, or serial network nodes using SNP\/SNP-X protocols without requiring an auxiliary communications module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMounting the IC693PWR324 requires inserting the rear tabs into the far-left slot of the Series 90-30 baseplate and pushing the module firmly into place until the bottom release lever locks tightly. Connect incoming primary power (100-240 VAC or 125 VDC) to the screw terminals on the front terminal strip under the protective cover.\u003c\/p\u003e\n\u003cp\u003eMaintain a dedicated protective earth (PE) ground connection directly from the module grounding terminal to the main panel ground bar using a minimum 14 AWG conductor. Route AC input cables away from low-voltage I\/O lines by maintaining a 6-inch physical separation in wire troughs to limit electromagnetic interference. Verify that external 24 VDC relay power loops do not exceed total wattage limits when drawing power from the isolated outputs.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44486140395619,"sku":"IC693PWR324","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/38_d8098f10-e220-4c9b-a685-de9555628955.jpg?v=1787039400","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic693pwr324-series-90-30-30w-power-supply-module","provider":"AutoControl Global","version":"1.0","type":"link"}