{"product_id":"ge-fanuc-ic694tbb132-pacsystems-rx3i-36-pin-terminal-block-module","title":"GE Fanuc IC694TBB132 PACSystems RX3i 36-Pin Terminal Block Module","description":"\u003ch2\u003eGE Fanuc IC694TBB132 PACSystems RX3i Terminal Block Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for field conductor termination in PACSystems RX3i automation architectures, the \u003cstrong\u003eGE Fanuc IC694TBB132\u003c\/strong\u003e (\u003cstrong\u003eIC694TBB132\u003c\/strong\u003e Extended Box-style Terminal Block) provides direct physical\/electrical execution. It establishes a 36-pin screw-type wiring interface to route field signals directly to high-density discrete and analog I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC694TBB132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ General Electric (Emerson)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg (0.56 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e101.6 mm x 50.8 mm x 25.4 mm (4.0 in x 2.0 in x 1.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive passive wiring component\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eExtended box-style screw terminals (36 connection points)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Gauge\u003c\/td\u003e\n\u003ctd\u003e#14 to #26 AWG solid or stranded wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Strip Length\u003c\/td\u003e\n\u003ctd\u003e0.310 inches (7.87 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScrew Tightening Torque\u003c\/td\u003e\n\u003ctd\u003e7 lb-in (0.8 Nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Compatibility\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i and Series 90-30 high-density I\/O modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Controller Architecture \u0026amp; Bus Network Attributes\u003c\/h3\u003e\n\u003cp\u003eThis terminal block mounts directly to the front face of high-density I\/O modules, enabling rapid signal routing across the PACSystems RX3i backplane bus. The physical interface supports I\/O density scaling by securing 36 individual termination pins within a single module width. Integrated protective housing maintains firmware flash compatibility and backplane signaling stability by preventing stray copper strands from bridging adjacent channels or backplane trace connections.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the terminal block support Removal and Insertion Under Power (RIUP) during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: No, Removal and Insertion Under Power (RIUP) is not supported for this terminal block assembly. Field power and backplane supply must be de-energized prior to detaching the wiring block from the host I\/O module.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended conductor preparation for field wiring terminations?\u003c\/p\u003e\n\u003cp\u003eA: Strip field conductors to a clean length of 0.310 inches (7.87 mm) using #14 to #26 AWG solid or stranded wire, then torque the captive terminal screws to 7 lb-in.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eAlign the terminal block assembly with the front connector header of the designated RX3i or Series 90-30 high-density I\/O module. Push the unit firmly until the latch mechanisms engage completely. Strip wire insulation cleanly to 0.310 inches (7.87 mm) without damaging inner conductor strands. Insert prepared conductors into the cage terminals and tighten captive screws to a torque of 7 lb-in. Route all field wiring bundles neatly through cabinet wire ducts to prevent mechanical stress on terminal connection pins, ensuring proper earth grounding of shielded cables at the enclosure entry panel.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44480503906403,"sku":"IC694TBB132","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/525_62eff804-e395-407c-8090-b503f799b208.jpg?v=1786671533","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic694tbb132-pacsystems-rx3i-36-pin-terminal-block-module","provider":"AutoControl Global","version":"1.0","type":"link"}