{"product_id":"ge-fanuc-ic695alg628-pacsystems-rx3i-analog-input-modules","title":"GE Fanuc IC695ALG628 PACSystems RX3i Analog Input Modules","description":"\u003ch2\u003eGE Fanuc IC695ALG628 PACSystems RX3i Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for precise process automation and industrial control in PACSystems RX3i networks, the \u003cstrong\u003eGE Fanuc IC695ALG628\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG628\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 140 x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e34 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Ranges\u003c\/td\u003e\n\u003ctd\u003e+\/-10 V, 0-10 V, +\/-5 V, 0-5 V, 1-5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunications\u003c\/td\u003e\n\u003ctd\u003eHART protocol enabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, ATEX, Zone 2, C1D2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe IC695ALG628 optimizes data acquisition efficiency by managing 8 distinct analog input loops inside a single-slot RX3i chassis footprint. The module handles high-precision voltage and current conversion loops through a 16-bit resolution engine, enabling tight scaling metrics across diverse industrial transmitter layouts. System integration routines utilize explicit firmware flash compatibility architectures across the RX3i backplane bus to ensure uninterrupted parameter polling, preventing data collision when parallel diagnostic routines extract HART-modulated smart variables alongside primary variables.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the interface maintain isolation across separate transmitter connections?\u003c\/p\u003e\n\u003cp\u003eA: The hardware employs dedicated channel-to-channel isolation architecture across all 8 inputs. This internal electrical barrier blocks ground loop propagation and attenuates common-mode electrical noise across adjacent field loops.\u003c\/p\u003e\n\u003cp\u003eQ: What specific power demands does the module impose on the RX3i rack power supply?\u003c\/p\u003e\n\u003cp\u003eA: The module draws its operating power directly from the active RX3i backplane bus, demanding a low current load of approximately 34 mA at 5 VDC during standard signal execution.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDe-energize the central PACSystems RX3i rack and all auxiliary external instrumentation loops before mounting or extracting the module.\u003c\/li\u003e\n\u003cli\u003eInsert the unit into the chosen backplane slot along the molded mechanical alignment tracks, exerting uniform force until the rear bus connector seats tightly.\u003c\/li\u003e\n\u003cli\u003eConnect all field instruments using multi-conductor twisted pairs with individual shields, grounding the copper shields exclusively at the designated enclosure marshaling ground strip.\u003c\/li\u003e\n\u003cli\u003eSeparate low-voltage analog instrumentation wiring (4-20 mA \/ 0-10 V) from high-power AC terminal conductors within the wire routing trays to mitigate inductive signal distortion.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872699547747,"sku":"IC695ALG628","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/397._d41f9f61-0460-4a86-9978-1436ee4ac6be.jpg?v=1764913397","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic695alg628-pacsystems-rx3i-analog-input-modules","provider":"AutoControl Global","version":"1.0","type":"link"}