{"product_id":"ge-fanuc-ic695alg728-pacsystems-rx3i-8-channel-ao-module","title":"GE Fanuc IC695ALG728 PACSystems RX3i 8-Channel AO Module","description":"\u003ch2\u003eGE Fanuc IC695ALG728 PACSystems RX3i Series\u003c\/h2\u003e\n\u003cp\u003eConfigured for high-accuracy voltage and current loop execution in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695ALG728\u003c\/strong\u003e (\u003cstrong\u003eIC695ALG728\u003c\/strong\u003e Analog Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695ALG728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States (USA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142 mm x 100 mm x 34 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog output channels (non-isolated, shared common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC, 4 to 20 mA (with superimposed HART)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit Digital-to-Analog conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL, CE, ATEX Zone 2, CSA, Marine (ABS, BV, DNV, GL, KRS, LR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe architecture links multiple analog loops directly to the RX3i chassis while managing data alignment alongside preset backplane bus communication velocity parameters. To ensure uninterrupted command execution during heavy multi-channel scaling and dense I\/O density scaling profiles, the digital processing engine syncs field-side variables with current firmware flash compatibility versions. The integrated circuitry enables real-time device diagnostic transmission across deterministic networks, supporting HART digital messaging over the analog current path without altering standard output loop response.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module prevent register data loss during standard firmware flash compatibility synchronization?\u003c\/p\u003e\n\u003cp\u003eA: System engineers must fully halt the active controller execution path and disconnect active field wiring blocks before starting a firmware update sequence to avoid corruption across the backplane bus communication velocity rails.\u003c\/p\u003e\n\u003cp\u003eQ: Is online hot-swap module replacement supported for the IC695ALG728 within an active RX3i rack layout?\u003c\/p\u003e\n\u003cp\u003eA: While the PACSystems RX3i backplane permits hot-swapping under specific software configurations, field safety steps require isolating external 4 to 20 mA loops prior to extraction to prevent high-current transients across the shared common reference.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Insertion and Connector Engagement:\u003c\/strong\u003e Slide the module firmly into the targeted RX3i slot assignment. Ensure the upper and lower plastic retaining clips engage fully with the chassis perimeter rail to preserve proper structural balance under vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART Loop Shield Continuity:\u003c\/strong\u003e Terminate all external twisted-pair signal loop shields at the designated cabinet grounding block. Avoid tying shields to the module common terminals to limit noise ingress into the 16-bit D\/A converters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConductor Separation and Routing:\u003c\/strong\u003e Route the 8-channel analog signal lines through isolated low-voltage wire guides, maintaining physical distance from parallel high-voltage AC motor lines.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872403882083,"sku":"IC695ALG728","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/380_984ab237-1103-4229-b682-e1d4b2e64c7e.jpg?v=1764900845","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic695alg728-pacsystems-rx3i-8-channel-ao-module","provider":"AutoControl Global","version":"1.0","type":"link"}