{"product_id":"ge-fanuc-ic695cpu310-fs-300mhz-cpu-processor-module","title":"GE Fanuc IC695CPU310-FS 300MHz CPU Processor Module","description":"\u003ch2\u003eGE Fanuc IC695CPU310-FS PACSystems RX3i CPU Processor Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for core logic execution and real-time control in PACSystems RX3i backplane architectures, the \u003cstrong\u003eGE Fanuc IC695CPU310-FS\u003c\/strong\u003e (\u003cstrong\u003eIC695CPU310\u003c\/strong\u003e CPU Processor Module) provides direct physical\/electrical execution for up to 320 local and expansion I\/O channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695CPU310-FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm x 115 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W maximum @ 24 VDC (+\/-10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e300 MHz RISC Architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Memory\u003c\/td\u003e\n\u003ctd\u003e2 MB User Logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e128 MB RAM, 64 MB Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Backup\u003c\/td\u003e\n\u003ctd\u003eIncluded for non-volatile RAM data retention\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDual RS-232\/RS-485 serial ports, 1x Ethernet port, 1x USB programming port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols\u003c\/td\u003e\n\u003ctd\u003eModbus RTU\/TCP, SNP, Ethernet Global Data (EGD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e320 local I\/O points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe processor resides in the dedicated CPU slot of the PACSystems RX3i baseplate, driving high-speed PCI backplane bus transactions to coordinate system-wide scan cycles. Firmware flash compatibility allows real-time execution of complex instruction sets, online logic modification, and automated diagnostics without interrupting cycle execution. Integrated dual serial and Ethernet channels manage deterministic network synchronization, offloading communication overhead from the primary 300 MHz engine to maintain consistent logic solution times.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC695CPU310-FS module be extracted or inserted while the RX3i system rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No, the CPU module does not support hot-swapping. Rack supply power must be completely turned off before removing or installing the processor module to prevent memory corruption or hardware damage.\u003c\/p\u003e\n\u003cp\u003eQ: How is logic program memory retained during a main power failure?\u003c\/p\u003e\n\u003cp\u003eA: Non-volatile user memory is preserved via battery-backed RAM, which maintains user logic and system memory registers when backplane operating voltage drops below specified thresholds.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic indicators are accessible on the module front panel during operation?\u003c\/p\u003e\n\u003cp\u003eA: Built-in LED status indicators provide visual feedback for CPU operation, run\/stop states, battery condition, forced signals, and system fault alerts.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the main power supply to the RX3i baseplate is isolated prior to installation. Align the IC695CPU310-FS circuit board edge with the CPU slot guide rails and push firmly until the rear multi-pin backplane connector seats tightly into the rack socket. Secure the module retention screw to maintain earth continuity across the mounting frame. Route Ethernet and serial cables through cable management channels, maintaining a separation distance of at least 30 cm from high-voltage AC conductors and drive wiring. Ground all communication shielding to the cabinet ground bus bar to suppress ambient electromagnetic noise.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43876706123875,"sku":"IC695CPU310-FS","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/203_b3191b53-6432-4d04-9add-d81bb46f8eac.jpg?v=1765161646","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic695cpu310-fs-300mhz-cpu-processor-module","provider":"AutoControl Global","version":"1.0","type":"link"}