{"product_id":"ge-fanuc-ic695pbm300-profibus-master-new-original-stock","title":"GE Fanuc IC695PBM300 PROFIBUS Master | New \u0026 Original Stock","description":"\u003ch2\u003eGE Fanuc IC695PBM300 PROFIBUS DP Master Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PBM300-CC\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PBM300\u003c\/strong\u003e PROFIBUS Master Module, serves as the primary \u003cstrong\u003eIC695\u003c\/strong\u003e PROFIBUS Master Module utilized to execute high-speed industrial network data exchange across PACSystems RX3i platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PBM300-CC \/ IC695PBM300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc (Emerson Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg (0.31 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PACSystems RX3i single-slot module dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.45 W (440 mA @ 3.3 VDC backplane current draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003ePROFIBUS-DP Master Module (DP-V1 supported)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Line\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Compatibility\u003c\/td\u003e\n\u003ctd\u003eRX3i PCI Universal Backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Baud Rates\u003c\/td\u003e\n\u003ctd\u003e9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, 12M Baud\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlave Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 125 PROFIBUS-DP slave nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode I\/O Buffer Limits\u003c\/td\u003e\n\u003ctd\u003e244 Bytes input \/ 244 Bytes output per individual slave\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Aggregate Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 3584 input bytes and 3584 output bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Slave Config Memory\u003c\/td\u003e\n\u003ctd\u003eApproximately 9 KB limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x PROFIBUS Master Port, 1 x RS-232 Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostics Mechanisms\u003c\/td\u003e\n\u003ctd\u003eSlave Status Bit Array, Network\/Master counters, Slave Addresses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PBM300\u003c\/strong\u003e links legacy field networks into modern Profinet or EtherNet\/IP deterministic networks via the PACSystems RX3i central processor. Operating over the high-speed RX3i PCI backplane bus, this module provides deterministic synchronization for up to 125 field nodes while maintaining isolated diagnostic monitoring counters. Large-scale I\/O density scaling is managed within a strict 9 KB slave configuration memory limit, allowing aggregate cyclic data routing of up to 3584 input and 3584 output bytes without degrading host backplane bus communication velocity. The onboard processor supports firmware flash compatibility via standard engineering tools to enforce execution constraints across mixed-vendor DP-V1 networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the minimum programming software version parameters required to configure the network matrix?\u003c\/strong\u003e A: Hardware parameterization and slave node mapping require Machine Edition Logic Developer PLC version 5.0 Build 3227 SP2 or later. If deploying customized C-coded control strategies, the application must be compiled using the PLC C Toolkit Version 4.00 Build 50A1 or later.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is Direct Directed Input\/Output (DOIO) execution supported through this module interface?\u003c\/strong\u003e A: No. DOIO functionality is entirely unsupported by the embedded module firmware. Utilizing a DOIO function block targeting this interface inside the application logic will instantly return an execution error status word to the host CPU block.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Insertion Constraints:\u003c\/strong\u003e Ensure the unit is installed solely within a standard PCI-compatible slot of an RX3i Universal Backplane. Turn off all system power supplies prior to seating the single-slot module to prevent backplane bus transients.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Cable Shield Termination:\u003c\/strong\u003e Ground the outer copper braided shield of the PROFIBUS network cable directly to the metal housing of the DB-9 industrial connector. Ensure line termination switches are flipped to the active position (\"ON\") exclusively at the physically first and last nodes of the network segment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVibration and Thermal Mitigation:\u003c\/strong\u003e Secure the module faceplate using the integrated chassis mounting screws. Maintain unrestricted perimeter airflow patterns around the RX3i enclosure to prevent internal module operating temperatures from exceeding the 60 deg C performance limit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44258825011299,"sku":"IC695PBM300-CC","price":420.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/69_44ced53e-f1f6-4e54-a101-200b9ca8b171.jpg?v=1781487459","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic695pbm300-profibus-master-new-original-stock","provider":"AutoControl Global","version":"1.0","type":"link"}