{"product_id":"ge-fanuc-ic695psa140ca-ic695psa140-rx3i-base-power-supply","title":"GE Fanuc IC695PSA140CA IC695PSA140 RX3i Base Power Supply","description":"\u003ch2\u003eGE Fanuc IC695PSA140CA PACSystems RX3i Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for power conversion and load distribution in PACSystems RX3i platforms, the \u003cstrong\u003eGE Fanuc IC695PSA140CA\u003c\/strong\u003e (\u003cstrong\u003eIC695PSA140\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution. Mounted on the RX3i Universal Backplane, the unit converts a wide-range AC or DC input source into regulated 5 VDC power to energize CPU modules, expansion units, and active local bus components across the rack frame.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140CA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Production\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 x 33 x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W input power (40 W load output capacity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC (47 to 63 Hz) or 100 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eRegulated 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 8 A @ 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 VAC input-to-output isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Rating\u003c\/td\u003e\n\u003ctd\u003e6 A per terminal max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation Modes\u003c\/td\u003e\n\u003ctd\u003eStandalone, Load Sharing, Redundancy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140CA stabilizes power distribution across internal backplane buses, ensuring that voltage ripple does not affect backplane bus communication velocity during high-density I\/O switching cycles. When paired with a secondary power supply on the universal backplane, the unit executes active load sharing and seamless power redundancy to preserve logic execution without interrupting active I\/O density scaling or module scan routines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC695PSA140CA supply power to external 24 VDC field devices directly?\u003c\/p\u003e\n\u003cp\u003eA: No, the module provides regulated 5 VDC output exclusively to the RX3i backplane bus power rails for internal module logic and processor power.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IC695PSA140CA handle module replacement in redundant power configurations?\u003c\/p\u003e\n\u003cp\u003eA: In dual power supply arrangements on a universal backplane, one supply can be powered down or removed without dropping the system backplane voltage, allowing continuous controller operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIsolate all primary AC and DC mains power feeds before making terminal block connections or seating the power supply into the universal backplane.\u003c\/li\u003e\n\u003cli\u003eConnect a heavy-gauge copper grounding wire directly from the module functional earth terminal to the main cabinet ground busbar.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage selection and terminal polarity before applying power to prevent internal fuse tripping or MOV degradation.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50 mm of unobstructed vertical clearance above and below the module enclosure to ensure adequate thermal convection cooling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44553584640099,"sku":"IC695PSA140CAE","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/48_be3759e1-5be9-48e7-b893-1913cfb0eadc.jpg?v=1788514843","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic695psa140ca-ic695psa140-rx3i-base-power-supply","provider":"AutoControl Global","version":"1.0","type":"link"}