GE Fanuc IC697CMM742-HK Network Module Overnight Ship
Manufacturer: GE Fanuc
-
Part Number: IC697CMM742-HK
Condition:New with Original Package
Product Type: Industrial Ethernet Controllers
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Product Overview
The GE Fanuc IC697CMM742-HK serves as a high-performance, single-slot industrial Ethernet communications interface module designed for the Series 90-70 programmable logic controller family. This module establishes a direct network connection between the central 90-70 CPU rack and modern factory network infrastructures. It facilitates high-speed data transfer across peer-to-peer PLC links, supervisor SCADA platforms, human-machine interfaces (HMIs), and remote enterprise management databases.
The hardware houses three distinct physical network media interfaces to match varying legacy and modern field wiring setups. It supports standard Ethernet protocols, integrates Ethernet Global Data (EGD) for rapid deterministic transfers, and includes localized diagnostic serial interfaces. The "-HK" designation represents a late-revision engineering lot featuring optimized silicon logic, heightened electromagnetic compliance, and complete backward compatibility with older hardware revisions.
We supply this network component exclusively in 100% brand new, original, and factory-sealed condition. This guarantees pristine physical ports, untouched internal circuit fuses, and complete operational lifetimes in high-demand industrial networks.
Technical Specifications
The table below logs the precise data communication, electrical, physical, and environmental parameters for the IC697CMM742-HK interface hardware. All values utilize standard ASCII formatting.
| Parameter | Specification Details |
| Manufacturer | GE Fanuc / Emerson Automation Solutions |
| Model Number | IC697CMM742-HK |
| Product Line | Series 90-70 PLC System |
| Module Type | Industrial Ethernet Communications Interface |
| Active Network Transceiver Allowance | 1 active port at any single time |
| 10Base-T Port Medium | RJ-45 Connector (IEEE 802.3 CSMA/CD) |
| 10Base-2 Port Medium | BNC Coaxial ThinWire Connection |
| AUI Port Medium | 15-pin D-sub (Supports external transceivers) |
| Onboard Serial Diagnostics | 1 x RS-232 Station Manager, 1 x RS-485 Load Port |
| Primary Communication Protocols | TCP/IP, SRTP, Modbus TCP, EtherNet/IP, Profinet, UDP |
| Deterministic Data Support | Ethernet Global Data (EGD) |
| Front-Panel Diagnostic Indicators | MODULE OK, LAN ONLINE, SERIAL ACTIVE, STATUS LEDs |
| Local Reinitialization Method | Front-panel pushbutton restart latch |
| Logic Backplane Power Draw | +5 VDC at 2.0 Amps typical |
| Transceiver Auxiliary Power Draw | +12 VDC at 0.5 Amps maximum (powers AUI link) |
| Internal Electrical Circuit Protection | 5 x 20 mm, 250V, 1.0A slow-acting fuse |
| Ambient Operating Temperature Range | -20 to +70 degrees Celsius |
| Ambient Operating Humidity Range | 5% to 95% RH, non-condensing |
| Hardware Physical Footprint | Occupies 1 standard slot in 90-70 CPU rack |
| Module Physical Dimensions | 250 mm x 175 mm x 60 mm |
| Net Hardware Weight | 0.54 kg (1.19 lbs) |
Engineering Advantages
- Flexible Multi-Media Migration Path: The module incorporates three separate port types—RJ-45 (10Base-T), BNC Coaxial (10Base-2), and a 15-pin AUI port. This built-in hardware flexibility allows facility engineers to upgrade legacy plant networks from old coaxial or thickwire cabling to modern twisted-pair infrastructure without changing the primary PLC module hardware.
- Onboard Protocols for Multi-Brand Integration: The processor firmware concurrently handles distinct industrial communication stacks, including SRTP, Modbus TCP, and EtherNet/IP. This multi-protocol engine enables the Series 90-70 PLC to exchange runtime registers with diverse third-party field devices, remote telemetry units, and cross-platform controllers.
- High-Speed Deterministic EGD Delivery: The module utilizes Ethernet Global Data (EGD) structures to coordinate rapid, clock-synchronized data exchanges. This capability ensures fast transmission of time-critical plant parameters, eliminating communication lag in complex process-control configurations and highly synchronized assembly setups.
- Extended Industrial-Grade Thermal Engineering: Upgraded internal trace components allow the module to operate continuously within a broad thermal envelope from -20 up to +70 degrees Celsius. This resilience guarantees stable communication up-time in extreme manufacturing layouts, unconditioned remote terminal cabinets, and heavy-industry processing spaces.
FAQs
- Is this IC697CMM742-HK network card a brand new original factory piece?
- Yes. We sell the IC697CMM742-HK module strictly in 100% brand new, authentic, original factory-sealed condition. It arrives in its unopened manufacturer packaging to confirm that internal isolation components, port solder joints, and onboard microprocessors have never seen operational use.
- Can I order this module with overnight shipping if my plant is facing an emergency shutdown?
- Yes. We maintain this critical network module in stock and offer expedited overnight shipping options to minimize plant downtime. Select priority shipping at checkout to secure immediate dispatch from our warehouse fulfillment center.
- Can I transmit data through the RJ-45 port and the BNC coaxial port at the same time?
- No. While the module provides three physical network port choices to simplify field installation, the internal processing logic activates only one network media path at a time. The module automatically routes data traffic through the single port connected during system initialization.
- What function do the RS-232 and RS-485 serial interfaces serve on an Ethernet module?
- The serial interfaces provide isolated access channels for module maintenance and diagnostics. The RS-232 Station Manager port allows technicians to monitor live network traffic and check communication stats via a terminal program, while the RS-485 port handles field-level firmware upgrades without disrupting the main Ethernet lines.