{"product_id":"ge-fanuc-ic697mdl340-series-90-70-digital-input-module","title":"GE Fanuc IC697MDL340 Series 90-70 Digital Input Module","description":"\u003ch2\u003eGE Fanuc IC697MDL340 G Series 90-70\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC697MDL340 G\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC697MDL340\u003c\/strong\u003e Digital Input Module, operates as a dedicated hardware component for 24 VDC discrete signal interface within Series 90-70 PLC backplane networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697MDL340 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30\/90-70 single-slot width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 mA @ +5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e32 digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (positive logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Thresholds\u003c\/td\u003e\n\u003ctd\u003eON \u0026gt;= 15 VDC, OFF \u0026lt;= 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eOptical isolation, 250 VAC continuous (field to logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module directly interfaces with the Series 90-70 backplane bus communication velocity architecture, transferring 32-point input status bitmaps into the CPU image table within sub-millisecond scan intervals. Integrated optocouplers maintain continuous 250 VAC galvanic isolation between field-side input circuits and the internal backplane logic, preventing high-voltage electrical noise or inductive switching spikes from corrupting signal lines. Firmware flash compatibility across the Series 90-70 backplane guarantees deterministic state execution and rapid diagnostic polling via front-panel LED indicators.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the backplane current draw for this input module?\u003c\/p\u003e\n\u003cp\u003eA: The module draws approximately 120 mA from the internal +5 VDC backplane rail to power system-side logic and optical isolator circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 24 VDC inputs accept negative logic (sinking) wiring configurations?\u003c\/p\u003e\n\u003cp\u003eA: No. The channel input circuitry is configured specifically for positive logic (sourcing) 24 VDC discrete inputs, requiring field switches to route positive voltage to individual input points.\u003c\/p\u003e\n\u003cp\u003eQ: Is hot-swapping permitted for this module during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the rack backplane and field wiring circuits must be switched off before removing or installing the module to prevent electrical arcing and backplane bus fault conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the module securely in any available I\/O slot of the Series 90-70 baseplate. Route 24 VDC field input wiring in shielded, twisted-pair cables, keeping discrete signal lines separate from high-voltage AC cables to minimize electromagnetic coupling. Connect cable shields to the main enclosure earth ground bus bar at a single point only. Ensure the removable terminal block is fully seated and secured via retaining screws to maintain stable electrical contact under operational industrial vibration.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44581102747747,"sku":"IC697MDL340","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/280_a4a26ffb-44da-41eb-a570-98c9797464d9.jpg?v=1789092558","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic697mdl340-series-90-70-digital-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}