{"product_id":"ge-fanuc-ic698psd300-pacsystems-rx7i-power-supply-module","title":"GE Fanuc IC698PSD300 PACSystems RX7i Power Supply Module","description":"\u003ch2\u003eGE Fanuc IC698PSD300 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC698PSD300\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC698PSD300\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power regulation and distribution within PACSystems RX7i PLC racks. This unit converts incoming AC or DC supply voltage into regulated 24 VDC output to sustain backplane operations and I\/O module functionality.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC698PSD300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Manufacturing Sites\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.31 kg to 1.88 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e101.6 mm x 152.4 mm x 76.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e300 W (Maximum Output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC (50\/60 Hz) or 100-370 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e12.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Firmware Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module maintains synchronized communication with the PACSystems RX7i backplane, transmitting diagnostic data regarding health status, undervoltage, and thermal thresholds. The architecture supports internal firmware monitoring to verify compatibility with existing CPU rack configurations. The module manages deterministic power delivery to prevent communication latencies across the backplane bus during high-density I\/O switching cycles, ensuring that firmware-based protection logic remains active during operational fluctuations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC698PSD300 support N+1 redundancy?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports parallel operation with a second unit, facilitating automatic load sharing and seamless failover in the event of a primary module fault.\u003c\/p\u003e\n\u003cp\u003eQ: Is the module capable of hot-swapping within the RX7i rack?\u003c\/p\u003e\n\u003cp\u003eA: While the module is designed for industrial rack mounting, ensure the rack power is isolated according to local safety protocols before attempting physical insertion or extraction to prevent backplane arcing.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle thermal dissipation?\u003c\/p\u003e\n\u003cp\u003eA: The device is rated for operation up to 70 deg C. Users must ensure adequate clearance within the cabinet as specified by the RX7i installation manual to maintain proper airflow across the heat sink profiles.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the rack slot is free of debris and properly aligned for the RX7i chassis interface.\u003c\/li\u003e\n\u003cli\u003eVerify that input supply wiring matches the specified AC\/DC voltage range before connection.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the integrated fastening mechanism to ensure structural stability under vibration.\u003c\/li\u003e\n\u003cli\u003eFor redundant applications, ensure both modules are connected to the same DC bus and verify load sharing via the PLC diagnostic software.\u003c\/li\u003e\n\u003cli\u003eApply appropriate shielding to input cables to minimize electromagnetic interference within the control cabinet.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43872807977059,"sku":"IC698PSD300","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/418_bfbfbb0f-2010-4903-a618-06e1817b2ac2.jpg?v=1764921190","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-fanuc-ic698psd300-pacsystems-rx7i-power-supply-module","provider":"AutoControl Global","version":"1.0","type":"link"}