{"product_id":"ge-ic200alg260d-versamax-analog-input-module","title":"GE IC200ALG260D VersaMax Analog Input Module","description":"\u003ch2\u003eGE IC200ALG260D VersaMax Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG260D\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG260\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for converting 4-20 mA analog transmitter signals into digital data within GE VersaMax PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG260D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg (0.66 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 66.8 x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA at 5 VDC (backplane current consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit A\/D conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e1 ms per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 min (channel-to-channel and channel-to-logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe module handles high I\/O density scaling by processing 16 isolated current channels within a single VersaMax carrier slot. It communicates directly over the backplane bus, transferring 12-bit converted data to the main CPU at an update rate of 1 ms per channel. Integrated firmware flash compatibility preserves internal parameter mapping and scaling registers during CPU scan cycles, preventing data corruption across extended backplane configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module require an external loop power supply for two-wire 4-20 mA transmitters?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module processes incoming 4-20 mA current signals through an internal 250 ohm input impedance load, but the loop excitation power must be supplied by an external 24 VDC power source.\u003c\/p\u003e\n\u003cp\u003eQ: What level of galvanic isolation protects the PLC backplane from field signal surges?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 250 VAC continuous isolation and withstands up to 1500 VAC for 1 minute between individual channels and between field-side input circuitry and the backplane logic ground.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFollow these installation standards to maintain signal integrity and avoid ground loops:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eSnap the carrier base firmly onto a standard 35 mm DIN-rail and ground the rail to the main panel earth connection.\u003c\/li\u003e\n\u003cli\u003eWire 4-20 mA field transmitter leads using twisted, shielded pair cables to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eTerminate signal cable shields strictly at one end—preferably at the PLC cabinet grounding bar—to avoid noise induced by ground potential differences.\u003c\/li\u003e\n\u003cli\u003eKeep analog signal wiring physically separated from high-voltage AC lines and motor drive outputs by maintaining a minimum routing distance of 200 mm.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44458530898019,"sku":"IC200ALG260D","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/485._bef7516e-f5ee-4de4-9bf1-13cf8e873901.jpg?v=1786350601","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic200alg260d-versamax-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}