{"product_id":"ge-ic200alg266-versamax-15-channel-analog-input-module","title":"GE IC200ALG266 VersaMax 15-Channel Analog Input Module","description":"\u003ch2\u003eGE IC200ALG266 VersaMax Analog Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC200ALG266\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200ALG266\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for multi-channel current signal acquisition within VersaMax I\/O networks. The unit processes field sensor signals across 15 single-ended channels, translating analog current inputs into digital data registers via a 15-bit resolution A\/D converter.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG266\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE) \/ VersaMax\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.69 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm x 66.8 mm x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA to 150 mA max from 5 VDC backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e15-Channel Analog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e15 single-ended inputs (1 single group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (default) or 0-20 mA (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Signal Ranges\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Resolution\u003c\/td\u003e\n\u003ctd\u003e15 bits (0.3125 mV\/count digital resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e100K Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Update Rate\u003c\/td\u003e\n\u003ctd\u003e7.5 ms maximum for all channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConversion Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.3% typical at 25 deg C, 1.0% maximum at 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Response\u003c\/td\u003e\n\u003ctd\u003e24 Hz to 32 Hz (+\/-20%) 3dB corner frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiagnostic Capability\u003c\/td\u003e\n\u003ctd\u003eInternal hardware fault detection, loss of power, open-wire detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003eModule OK LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Dynamic Signal Filtering\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG266 executes rapid dynamic data conversion, relying on internal backplane bus communication velocity protocols to present updated 15-bit channel values to the main processor every 7.5 ms. The input stage utilizes internal active signal filtering with a 3dB corner frequency response tuned between 24 Hz and 32 Hz to reject high-frequency field noise. Integrated protection circuits safeguard the channel inputs against continuous overvoltage conditions up to 30 VDC and clamp accidental direct 24 VDC connections to a maximum current limit of 40 mA.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200ALG266 module supply 24 VDC loop power directly to external 2-wire field transmitters?\u003c\/p\u003e\n\u003cp\u003eA: No. The module operates entirely on logic-side power derived from the VersaMax 5 VDC backplane bus (drawing up to 150 mA) and does not contain an internal field loop power supply. Connected 2-wire field transmitters require an external 24 VDC power supply wired in series with the current loop.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle an open-wire condition when configured for 4-20 mA current mode?\u003c\/p\u003e\n\u003cp\u003eA: When operating in 4-20 mA input mode, the module continuously monitors loop integrity. If field wiring breaks and input current drops below the valid operating threshold, the hardware reports an open-wire fault diagnostic flag to the CPU and updates the module status registers.\u003c\/p\u003e\n\u003cp\u003eQ: Is channel-to-channel isolation supported across the 15 input terminals?\u003c\/p\u003e\n\u003cp\u003eA: No. The 15 input channels are arranged in a single-ended wiring configuration sharing a single common return path. Galvanic isolation rated at 250 VAC continuous (1500 VAC for 1 minute) is provided between the field-side input group, backplane logic, and frame ground.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBaseboard Installation\u003c\/strong\u003e: Align the rear interface connector with the VersaMax I\/O carrier slot and press the module firmly onto the baseboard until the retention latches snap into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJumper Range Selection\u003c\/strong\u003e: Set the onboard hardware jumpers prior to mounting to select between 4-20 mA and 0-20 mA current acquisition modes according to site requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Shielding\u003c\/strong\u003e: Route all 4-20 mA input loops using shielded twisted-pair conductors. Ground the cable shield drain wires at a single point on the enclosure grounding bar to prevent stray ground currents.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation\u003c\/strong\u003e: Maintain a minimum physical separation between 4-20 mA signal wiring runs and high-voltage AC power cables within cabinet wiring trunks to prevent electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Grounding\u003c\/strong\u003e: Ensure the DIN rail or enclosure mounting panel maintains a low-impedance connection to protective earth ground to establish a proper noise dissipation path for module isolation barriers.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44524095438947,"sku":"IC200ALG266","price":370.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/190._33ad84a6-ff75-4ff1-8899-75a732ed16a1.jpg?v=1787884488","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic200alg266-versamax-15-channel-analog-input-module","provider":"AutoControl Global","version":"1.0","type":"link"}