{"product_id":"ge-ic200chs003-system-input-output-carrier-module-base","title":"GE IC200CHS003 System Input Output Carrier Module Base","description":"\u003ch2\u003eGE IC200CHS003 VersaMax I\/O Carrier\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE IC200CHS003\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200CHS003\u003c\/strong\u003e Input\/Output Carrier, operates as a dedicated hardware component for physical module mounting and backplane electrical signal routing within VersaMax I\/O System networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200CHS003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.28 kg (0.63 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm W x 50 mm D x 66.8 mm H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via backplane interface)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eVersaMax I\/O Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 32 input\/output points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Termination\u003c\/td\u003e\n\u003ctd\u003eIntegrated connector style (36-pin connector \/ screw terminals)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current Per Point\u003c\/td\u003e\n\u003ctd\u003e2 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Power\/Ground Current\u003c\/td\u003e\n\u003ctd\u003e8 A per connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Transients Limit\u003c\/td\u003e\n\u003ctd\u003e300 VAC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous, 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Resistance\u003c\/td\u003e\n\u003ctd\u003eLess than 10 milliohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eAcrylonitrile Butadiene Styrene (ABS) plastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \u0026amp; Protection\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN rail or panel mount (Vertical orientation), IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Compliance\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Network Architecture\u003c\/h3\u003e\n\u003cp\u003eThe IC200CHS003 carrier routes high-speed data across internal module connections to ensure backplane bus communication velocity remains synchronized with the primary controller scan. Built-in physical keying prevents module misplacement while sustaining backplane power distribution across attached I\/O units. Hardware architecture maintains full firmware flash compatibility across installed processing units while optimizing I\/O density scaling options within localized cabinet configurations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the IC200CHS003 base unit process field data independently?\u003c\/p\u003e\n\u003cp\u003eA: No, this carrier unit provides physical structure, field termination, and backplane power routing. An active VersaMax I\/O module must seat onto the base to execute signal processing routines.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum continuous electrical ratings for the field terminal paths?\u003c\/p\u003e\n\u003cp\u003eA: Each individual termination point supports a rated current of 2 A, while power and ground routing paths sustain up to 8 A per connection with an internal contact resistance under 10 milliohms.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the carrier vertically onto a standard 35 mm DIN rail or fasten directly to a grounded enclosure backplate using mounting hardware. Secure field conductors to the integrated terminal connectors using designated wire gauges, separating 24 VDC control wiring from high-voltage power cables to mitigate EMI noise. Ensure the panel grounding conductor attaches to the primary cabinet ground bus bar before seating active VersaMax I\/O modules into the carrier base.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44524200001635,"sku":"IC200CHS003","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/195._564750d3-4070-4b22-9f2a-3aba7cc3d630.jpg?v=1787886890","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic200chs003-system-input-output-carrier-module-base","provider":"AutoControl Global","version":"1.0","type":"link"}