{"product_id":"ge-ic200gbi001-gj-versamax-genius-network-interface-module","title":"GE IC200GBI001-GJ VersaMax Genius Network Interface Module","description":"\u003ch2\u003eGE Fanuc IC200GBI001-GJ VersaMax Genius Network Interface Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for distributed field bus expansion in Genius I\/O networks, the \u003cstrong\u003eGE Fanuc IC200GBI001-GJ\u003c\/strong\u003e (\u003cstrong\u003eIC200GBI001\u003c\/strong\u003e Bus Interface Module) provides direct physical\/electrical execution. The module links VersaMax I\/O station racks directly to a Genius serial bus, managing serial network data exchange across designated controller address ranges.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200GBI001-GJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eRefer to device label\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.17 kg (0.38 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 mm x 90 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e+5 VDC @ 250 mA, +3.3 VDC @ 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eGenius I\/O bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Bus Address Range\u003c\/td\u003e\n\u003ctd\u003e0 to 31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rates\u003c\/td\u003e\n\u003ctd\u003e153.6 kbaud (extended); 153.6 kbaud, 76.8 kbaud, 38.4 kbaud (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 modules per rack, up to 8 racks total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory Limits\u003c\/td\u003e\n\u003ctd\u003e1024 discrete inputs, 1024 discrete outputs, 128 bytes analog I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Scan Capacity\u003c\/td\u003e\n\u003ctd\u003e128 bytes input \/ 128 bytes output per bus scan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminating Resistors\u003c\/td\u003e\n\u003ctd\u003eSelectable 75, 100, 120, or 150 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Controllers\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i, PACSystems RX7i, Series 90-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Execution\u003c\/h3\u003e\n\u003cp\u003eThe network interface module coordinates backplane bus communication velocity across attached VersaMax I\/O carriers to maintain rapid I\/O scan synchronization. Internal logic decodes data frames from Series 90-70 or PACSystems controllers and transfers discrete and analog states across the backplane bus within tight update windows. Firmware flash compatibility supports uniform hardware handshaking and preserves deterministic response times during multi-rack field scans.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is physical line termination applied on the Genius serial network trunk?\u003c\/p\u003e\n\u003cp\u003eA: The module supports software-selectable or jumper-configured terminating resistor values of 75, 100, 120, or 150 ohms at both physical ends of the daisy-chain network segment to prevent signal reflections.\u003c\/p\u003e\n\u003cp\u003eQ: What power rails must the VersaMax carrier supply to operate this module?\u003c\/p\u003e\n\u003cp\u003eA: The backplane must supply two DC voltage levels: +5 VDC drawing up to 250 mA and +3.3 VDC drawing up to 10 mA for low-voltage communication logic circuits.\u003c\/p\u003e\n\u003cp\u003eQ: How many local I\/O modules can a single Genius bus interface manage?\u003c\/p\u003e\n\u003cp\u003eA: The interface manages up to 8 I\/O modules per rack and scales across up to 8 connected racks, supporting up to 2048 total discrete points (1024 inputs \/ 1024 outputs) and 128 bytes of analog memory.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the network interface unit onto a standard 35 mm DIN rail or panel subplate using the primary slot of the VersaMax baseplate.\u003c\/li\u003e\n\u003cli\u003eWire the dual Genius bus terminals in a sequential daisy-chain topology using shielded twisted-pair communication cable.\u003c\/li\u003e\n\u003cli\u003eConnect the cable drain wire to the earth ground tab on the terminal block to establish optical isolation and shield protection against industrial electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify that the serial bus address (0 to 31) and baud rate match the host controller hardware configuration prior to applying bus power.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44453352144995,"sku":"IC200GBI001-GJ","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/468._2b96c54f-ff00-4171-bd30-072340325bc9.jpg?v=1786085960","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic200gbi001-gj-versamax-genius-network-interface-module","provider":"AutoControl Global","version":"1.0","type":"link"}