{"product_id":"ge-ic695mdl765-pacsystems-rx3i-digital-output-card","title":"GE IC695MDL765 PACSystems RX3i Digital Output Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE Fanuc IC695MDL765 functions as a high-density discrete output control module for the PACSystems RX3i programmable automation controller platform. This module provides 32 isolated digital output channels on a single slot card, serving as the core execution driver for field-level industrial loads. Automation engineers deploy this card to trigger external interposing relays, hydraulic solenoids, pneumatic valves, indicator lamps, and motor starter contactors across automated processing cells.\u003c\/p\u003e\n\u003cp\u003eThe design coordinates real-time signal transmission over the high-speed RX3i system bus. It combines dense circuit placement with individual channel galvanic isolation and advanced diagnostic fault-monitoring logic.\u003c\/p\u003e\n\u003cp\u003eWe deliver this automation component exclusively in \u003cstrong\u003e100% brand new, original, and factory-sealed\u003c\/strong\u003e condition inside its authentic manufacturer box. This standard guarantees unblemished solid-state electronic switches, pristine terminal interfaces, and zero operational hours on the internal monitoring firmware.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe table below logs the precise electrical, mechanical, environmental, and thermal parameters for the IC695MDL765 hardware module. All data uses standard ASCII formatting.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003eGE Fanuc \/ Emerson Automation Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eModel Number\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eIC695MDL765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eController Platform Family\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003ePACSystems RX3i Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eProduct Functional Type\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003eDiscrete Output Module with Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eTotal Hardware Output Points\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e32 Isolated Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eSwitching Circuit Topology\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003eRelay \/ Solid-State (Configuration dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003eNominal Operating Voltage\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eMaximum Continuous Current Rating\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e0.5 Amps maximum per individual point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eMaximum Aggregate Module Current\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e16.0 Amps total per complete card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eHardware Isolation Protection\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003eComplete galvanic isolation between channels and system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"12\"\u003eIntegrated Hardware Diagnostics\u003c\/td\u003e\n\u003ctd data-row=\"12\"\u003eIndividual output status monitoring and fault detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"13\"\u003eExternal Wiring Termination Mode\u003c\/td\u003e\n\u003ctd data-row=\"13\"\u003eRemovable Terminal Block (RTB) connection mechanism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"14\"\u003eModule Mechanical Dimensions\u003c\/td\u003e\n\u003ctd data-row=\"14\"\u003e5 inches x 7 inches (Standard RX3i single-slot size)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"15\"\u003eNet Component Weight\u003c\/td\u003e\n\u003ctd data-row=\"15\"\u003e0.7 kg (1.54 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"16\"\u003ePermissible Cabinet Temperature\u003c\/td\u003e\n\u003ctd data-row=\"16\"\u003e0 to +60 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"17\"\u003ePermissible Warehouse Storage Temperature\u003c\/td\u003e\n\u003ctd data-row=\"17\"\u003e-40 to +85 degrees Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"18\"\u003ePermissible Atmospheric Humidity\u003c\/td\u003e\n\u003ctd data-row=\"18\"\u003e5% to 95% relative humidity, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"19\"\u003ePrimary Assembly Location\u003c\/td\u003e\n\u003ctd data-row=\"19\"\u003eUnited States of America (USA) \/ GE Intelligent Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Channel Layout:\u003c\/strong\u003e Compressing 32 isolated output points into a single RX3i slot maximizes backplane space efficiency. This layout lets control cabinet designers configure high-density termination layouts, drastically cutting total panel space requirements and reducing the need for multiple rack expansions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGranular Real-Time Channel Diagnostics:\u003c\/strong\u003e The internal hardware tracks the actual operating status of each individual channel circuit, flashing localized fault flags back to the central CPU register table if a disruption occurs. This continuous monitoring identifies circuit exceptions instantly, cutting system troubleshooting and maintenance downtime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGalvanic Noise Isolation Barrier:\u003c\/strong\u003e Complete galvanic isolation separates the output channel circuits from the central RX3i processor bus. This design blocks inductive voltage kicks from large motor contactors and high-frequency field switching noise at the card edge, maintaining logic system integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStreamlined Maintenance with Removable Blocks:\u003c\/strong\u003e The module interfaces with external field wiring through a mechanical Removable Terminal Block (RTB). This architecture allows technicians to swap out the active electronics module during servicing without disconnecting individual field wires, preventing field miswiring errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIs this IC695MDL765 discrete output module a brand new factory item or refurbished stock?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eWe supply the IC695MDL765 module strictly in 100% brand new, original, authentic factory-sealed condition. The product ships inside its unopened manufacturer box to ensure that internal circuit links and firmware registers remain pristine.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCan this module supply the full 0.5 Amps across all 32 channels concurrently?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe module handles a maximum individual channel current of 0.5 Amps, but you must respect the total module current limit of 16.0 Amps aggregate. If your application switches all 32 channels simultaneously, you must budget the average continuous load per channel to a maximum of 0.5 Amps ($32 \\times 0.5\\text{ A} = 16.0\\text{ A}$) to prevent internal thermal overload.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWhat types of field faults can the internal diagnostic logic identify?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe diagnostic circuits track the active electrical states of individual channels to check for functional anomalies. Depending on your configuration and firmware settings, the module flags open-circuit wiring paths, output power losses, and channel configuration errors, sending these diagnostic reports directly to the RX3i CPU fault tables.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDoes this module ship with the Removable Terminal Block included in the box?\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThe core IC695MDL765 factory box contains the main isolated processor card block. The Removable Terminal Block (RTB) represents a separate mechanical part number. You must specify your required wiring terminal type (screw style or spring style) and order the matching terminal assembly to complete the panel installation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":43865464569955,"sku":"IC695MDL765","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/204_bdcc2c36-9e90-40f7-9cd7-a46d4846ac27.jpg?v=1764559205","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic695mdl765-pacsystems-rx3i-digital-output-card","provider":"AutoControl Global","version":"1.0","type":"link"}