{"product_id":"ge-ic695psa140-pacsystems-rx3i-multi-purpose-power-supply","title":"GE IC695PSA140 PACSystems RX3i Multi-Purpose Power Supply","description":"\u003ch2\u003eGE Fanuc IC695PSA140 PACSystems RX3i Power Supply Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC695PSA140\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC695PSA140\u003c\/strong\u003e Multi-Purpose Power Supply, operates as a dedicated hardware component for generating internal system bus voltages within PACSystems RX3i Universal Backplanes. The module converts universal 85 to 264 VAC or 100 to 300 VDC field power inputs into regulated +5.1 VDC, +3.3 VDC, and +24 VDC output rails to nourish active I\/O cards and central processing units.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC695PSA140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard RX3i Universal Rack Slot Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput Power: 70 W; Total Load Capacity: 40 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 VAC or 125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage Range\u003c\/td\u003e\n\u003ctd\u003e100 to 300 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e+5.1 VDC, +3.3 VDC, +24 VDC relay power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Support\u003c\/td\u003e\n\u003ctd\u003ePACSystems RX3i Universal Backplane Only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Units Per Rack\u003c\/td\u003e\n\u003ctd\u003eUp to four (4) power supply modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cp\u003eThe IC695PSA140 resides on the PACSystems RX3i backplane bus structure, providing stable regulated voltage tracks to preserve backplane bus communication velocity across high-density I\/O configurations. Advanced load-sharing logic allows up to four power supply modules to operate concurrently on a single universal rack slot architecture without introducing voltage fluctuations or network jitter. Internal power circuitry preserves firmware flash compatibility and execution determinism across connected EtherNet\/IP and PROFINET communication modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the IC695PSA140 support load sharing across an RX3i backplane?\u003c\/p\u003e\n\u003cp\u003eA: The onboard hardware architecture balances output current distribution when multiple IC695PSA140 units populate the same universal rack, enabling operational redundancy.\u003c\/p\u003e\n\u003cp\u003eQ: Can the IC695PSA140 module accept both AC and DC input power sources?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the universal input stage accepts line power across 85 to 264 VAC or 100 to 300 VDC without requiring hardware jumper adjustments.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum current rating per input wiring terminal on the unit?\u003c\/p\u003e\n\u003cp\u003eA: The input connection terminal block handles up to 6 Amperes per terminal point for field wiring conductors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eFirst, turn off primary feeder breakers and verify that no voltage exists across field input wiring leads. Next, align the rear guides of the IC695PSA140 module with the leftmost universal backplane slot, sliding the unit firmly backward until the top and bottom mounting latches snap locked. Then, land incoming 120\/240 VAC or 125 VDC power phase and neutral or DC conductors onto the removable screw terminal block, applying recommended torque limits. Finally, connect the protective earth ground lead directly to the rack earthing stud and route high-voltage supply lines separately from low-voltage signal lines.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44580972003427,"sku":"IC695PSA140","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/272._a070eb3e-f8f6-41ca-9555-615cc8e4cd7b.jpg?v=1789088597","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-ic695psa140-pacsystems-rx3i-multi-purpose-power-supply","provider":"AutoControl Global","version":"1.0","type":"link"}