GE IS200EDISG1A EX2100e/Mark VIe Exciter IO Terminal Board
GE IS200EDISG1A EX2100e/Mark VIe Exciter IO Terminal Board
GE IS200EDISG1A EX2100e/Mark VIe Exciter IO Terminal Board
/ 3

GE IS200EDISG1A EX2100e/Mark VIe Exciter IO Terminal Board

  • Manufacturer: GE Fanuc

  • Part Number: IS200EDISG1A

  • Condition:New with Original Package

  • Product Type: Digital I/O Cards

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE IS200EDISG1A EX2100e/Mark VIe Series

The GE IS200EDISG1A, also cataloged as the IS200EDIS Exciter Digital Input/Output Terminal Board, operates as a dedicated hardware component for digital input/output signal termination within EX2100e and Mark VIe exciter control platforms.

Hardware Specifications

Parameter Specification
Model IS200EDISG1A
Brand GE
Origin United States (USA)
Weight 4.00 kg (Shipping Weight)
Dimensions Approx. 28 to 30 cm width
Operating Temp -40 to +70 deg C
Power Consumption Driven by 28 VDC nominal backplane power
Channel Density 16 digital inputs and 16 digital outputs
Signal Input Type Dry contact inputs, 24 VDC logic
Signal Output Type Relay / solenoid drivers (24-125 VDC)
Response Latency < 1 ms for trip signals
Galvanic Isolation Channel-to-system and channel-to-channel isolation

Industrial Control and Drive Technical Attributes

The board architecture links discrete field circuits directly to the processing backbone, utilizing optimized backplane bus communication velocity parameters to process safety-critical shutdown triggers. To sustain deterministic network performance under full I/O density scaling conditions, the logic interfaces manage digital transitions through specific firmware flash compatibility matrices. This configuration eliminates latency jitters during multi-channel state changes and maintains precise sequence-of-events recording across the network.

Frequently Asked Questions

Q: Does the digital logic circuitry support online firmware flash compatibility verification while live?

A: No, firmware verification and memory flash updates must be executed during non-operational downtime periods to prevent transient corruption of the backplane bus communication velocity channels.

Q: What is the mechanical limitation for field wire termination sizes on this module?

A: The onboard terminal blocks accommodate standard industrial wiring up to 2.5 mm square (14 AWG) to ensure robust physical connectivity and minimize interface loop resistance.

Field Installation Guidelines

  • Chassis Grounding Structure: Secure the assembly onto the cabinet DIN-rail or rack matrix. Ensure the main chassis ground terminal establishes a metal-to-metal low-impedance connection directly to the master protective earth busbar.
  • Signal Cable Separation: Route low-voltage 24 VDC discrete input logic lines through separate physical wiring conduits isolated away from high-voltage 125 VDC solenoid output driver cables to suppress capacitive cross-talk.
  • Shield Drain Termination: Land external shield drain wires exclusively at the designated grounding bracket on the terminal board frame. Do not ground both ends of the cable shield to avoid forming ground loops.