GE IS200JPDBG1A Mark VI Power Distribution Board
Manufacturer: GE Fanuc
-
Part Number: IS200JPDBG1A
Condition:New with Original Package
Product Type: Power Distribution Boards
-
Country of Origin: USA
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
GE IS200JPDBG1A Mark VI/VIe Series
Configured for power distribution and signal routing in Mark VI/VIe networks, the GE IS200JPDBG1A (IS200JPDB Power Distribution Board) provides direct physical/electrical execution.
Suffix Breakdown & Model Matrix
- IS200: Standard product prefix designating a circuit board assembly manufactured by GE.
- JPDB: Functional board identifier denoting Junction Power Distribution Board design architecture.
- G1: Hardware group categorization mapping to specific component layouts and electrical current capacities.
- A: Functional revision level tracking engineering modifications and backward firmware compatibility.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | IS200JPDBG1A |
| Brand | GE |
| Origin | United States (USA) |
| Weight | 0.35 to 0.45 kg |
| Dimensions | 28 to 30 cm width |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | Driven by 28 VDC nominal input supply |
| Input Voltage | 28 VDC nominal (from Mark VI/VIe power supply) |
| Outputs | Multiple fused DC outputs to I/O packs and terminal boards |
| Fuse Rating | 2 to 5 A per channel (replaceable fuses) |
| Isolation | Channel-to-channel and channel-to-system isolation |
| Protection | Overcurrent and short-circuit protection |
Industrial Control and Drive Technical Attributes
The power architecture of this module interfaces with the backplane bus communication velocity configurations to maintain consistent sub-millisecond execution times. To manage high-density system configurations, the hardware employs strict firmware flash compatibility parameters that stabilize downstream voltage lines during multi-channel initialization. The centralized power routing path isolates transient switching feedback, maintaining systemic control grid stability across wide I/O density scaling profiles.
Frequently Asked Questions
Q: How is individual channel protection managed on this module?
A: Each output channel incorporates a dedicated replaceable fuse rated between 2 A and 5 A to isolate localized overcurrent faults and prevent system-wide propagation.
Q: Can this power distribution board be swapped while the backplane is active?
A: Live hot-swap execution is restricted; system power must be isolated in accordance with standard Mark VI enclosure safety procedures to prevent transient arc faults.
Field Installation Guidelines
- Enclosure Mounting: Install the hardware firmly into the designated rack slots within the Mark VI/VIe control cabinet. Verify all retention screws are torqued to spec to secure the chassis connection.
- Wiring and Isolation: Route the 28 VDC input lines using designated heavy-gauge industrial wiring. Separate low-voltage logic signal wires from primary distribution cables to avoid induction loops.
- Grounding Requirements: Establish a low-resistance path from the board ground plane to the master cabinet ground bar. Inspect all terminal junctions to confirm the integrity of the galvanic isolation barriers.