{"product_id":"ge-is200srlyh2a-12-channel-relay-module-new-original","title":"GE IS200SRLYH2A 12-Channel Relay Module | New \u0026 Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200SRLYH2A serves as the primary Simplex Relay Terminal Board within the Mark VI Speedtronic control ecosystem. This hardware functions as the critical power-switching interface between low-level controller logic and high-power field devices, including solenoids, trip circuits, alarms, and contactors. By providing 12 independent channels of high-reliability switching, the IS200SRLYH2A ensures the safety and precision of gas and steam turbine operations. We supply this module in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003econdition, shipped in factory-sealed packaging to guarantee optimal contact life and electrical performance.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe IS200SRLYH2A utilizes heavy-duty Form-C relay contacts to handle diverse AC and DC load requirements in industrial automation.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAttribute\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE (General Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel \/ Part Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS200SRLYH2A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE Mark VI Turbine Control System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Form-C (SPDT) Relay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eContact Rating\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A at 30 VDC \/ 0.5 A at 125 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-channel and Control-to-field Galvanic Isolation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C to +65°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5%–95% Non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 × 20 × 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEMI Shielding, Surge Suppression, Fault Monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 Kg (Shipping weight)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Power Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe IS200SRLYH2A employs full galvanic isolation between the Mark VI backplane and the field terminal strips. This barrier shields sensitive control processors from electrical noise and inductive kickback generated by switching solenoids or magnetic contactors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVersatile Form-C Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach of the 12 channels features Single-Pole Double-Throw (SPDT) contacts. This configuration allows engineers to utilize both Normally Open (NO) and Normally Closed (NC) circuits, providing maximum flexibility for safety interlocks and status feedback loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHardened Fault Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIntegrated hardware monitors the health of the relay coils and output states. This real-time diagnostic capability allows the Mark VI system to detect stuck contacts or coil failures immediately, preventing hazardous \"fail-to-trip\" scenarios.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Environmental Hardening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGE constructs the SRLY board with specialized EMI shielding and surge suppression circuitry. These features ensure the board maintains signal integrity even when mounted in the high-EMF (Electromagnetic Field) environments typical of turbine compartments and power generation halls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Serviceability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe modular board design and clear labeling facilitate rapid field wiring. Furthermore, the hot-swappable architecture allows maintenance teams to replace the terminal board without interrupting the entire control system, minimizing plant downtime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the IS200SRLYH2A ship with the factory seal intact?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Every IS200SRLYH2A unit we provide is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNew and Original in Factory Packing\u003c\/strong\u003e. This ensures the relay contacts have zero oxidation and have never been energized in a field environment, preserving the full 12-month factory warranty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this board for high-voltage AC switching?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe IS200SRLYH2A contacts are rated for 0.5 A at 125 VAC. For switching higher current AC loads or 220V\/440V circuits, you must use the IS200SRLYH2A to drive an interposing relay or contactor according to standard industrial safety practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the Simplex design differ from TMR versions?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe \"Simplex\" designation indicates that this board is intended for non-redundant terminal applications. While it integrates perfectly with the Mark VI platform, it does not include the voting hardware required for Triple Modular Redundant (TMR) safety configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the typical shipping lead time for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAs an in-stock component, the IS200SRLYH2A usually ships within 7 to 10 working days via premium carriers like FedEx or DHL. This ensures that critical turbine parts reach your site quickly to resolve maintenance emergencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":44098871591011,"sku":"IS200SRLYH2A","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/334_1371ba7d-5488-4492-8d7b-f6c15a399c2b.jpg?v=1775205802","url":"https:\/\/www.autocontrolglobal.com\/products\/ge-is200srlyh2a-12-channel-relay-module-new-original","provider":"AutoControl Global","version":"1.0","type":"link"}