GE Mark VI IS200TTURH1CFD Turbine Specific Primary Trip Board
GE Mark VI IS200TTURH1CFD Turbine Specific Primary Trip Board
GE Mark VI IS200TTURH1CFD Turbine Specific Primary Trip Board
/ 3

GE Mark VI IS200TTURH1CFD Turbine Specific Primary Trip Board

  • Manufacturer: GE Fanuc

  • Part Number: IS200TTURH1CFD

  • Condition:New with Original Package

  • Product Type: Turbine Terminal Boards

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE IS200TTURH1CFD Mark VI Turbine Terminal Board

The GE IS200TTURH1CFD, also cataloged as the IS200TTUR Turbine Specific Primary Trip Board, operates as a dedicated hardware component for overspeed trip execution and generator synchronization within Mark VI platforms. The terminal board routes physical signals from magnetic pickup speed sensors, generator voltage inputs, and bus synchronization paths directly to the designated PTUR or VTUR I/O packs. Conformal coating applied to the surface mount components prevents structural corrosion, securing the primary protection logic pathways against atmospheric moisture during active turbine operations.

Hardware Specifications

Parameter Specification
Model IS200TTURH1CFD
Brand GE
Origin USA
Weight 0.76 kg
Dimensions 330 mm x 178 mm x 42 mm
Operating Temp -30 to +65 deg C
Power Consumption 24 VDC nominal voltage input
Speed Sensor Range 2 Hz to 20 kHz magnetic pickup pulse rate
Speed Sensor Accuracy 0.05 % pulse rate tracking tolerance
Input Circuit Sensitivity 27 mV pk minimum detection threshold
Overspeed Trip Relays Three 125 VDC, 5 A resistive elements arranged in 2oo3 voting matrix
Electrical Isolation 1500 Vrms channel-to-backplane physical isolation barrier
Voltage Input Range 0 to 120 VAC, 50/60 Hz for generator and bus synchronization

Industrial Control Backplane Bus Architecture and I/O Scaling

The module handles critical safety parameters within the Mark VI backplane architecture by routing field sensor data directly through D-sub ribbon connectors to the primary processing packs. The terminal layout supports advanced I/O density scaling by multiplexing six to twelve independent pulse channels alongside the primary 120 VAC generator bus voltage feeds. Firm integration requires matching firmware flash compatibility levels across connected processing nodes, enabling the board to maintain deterministic trip transmission vectors without altering the baseline timing of the triple modular redundant safety loop.

Frequently Asked Questions

Q: How does the board process overspeed inputs to ensure a fail-safe shutdown sequence?

A: The circuit configuration routes speed inputs through three onboard 125 VDC relays wired in a two-out-of-three (2oo3) hardware voting matrix. If two independent channels register a trip condition, the circuit breaks the continuity path to actuate the primary turbine stop valves.

Q: Can the D-sub ribbon interfaces connecting the terminal board to the I/O pack be disconnected during live operation?

A: No, hot-swapping or disconnecting the interface cables while the turbine control loop is active can drop critical trip loops, causing an immediate emergency shutdown or interrupting the deterministic synchronization data flow to the host controller.

Q: What parameters govern the calibration of the speed sensor pulse circuits?

A: The input circuitry detects minimum pulse amplitudes down to 27 mV pk, scaling signal profiles up to 20 kHz. System configuration requires matching the tooth count of the rotor wheel within the software configuration parameters to ensure accurate shaft RPM metrics.

Field Installation Guidelines

  • Chassis Ground Grounding Steps: Install the terminal board into the panel framework using standard metal retention hardware, then establish a direct low-impedance connection from the ground terminals to the master enclosure copper bus bar to anchor the electrical reference point.
  • Magnetic Pickup Wiring Separation: Route the high-frequency speed sensor input wires through independent, grounded steel conduits. Physical isolation prevents high-voltage generator bus lines from inducing transient noise that could alter the 0.05 % speed tracking accuracy.
  • Ribbon Connector Jackscrews: Align the D-sub ribbon interface plugs precisely with the board headers before insertion. Fasten all mechanical retention hardware securely to prevent ambient machine vibrations from creating loose contacts on the primary safety lines.
  • Terminal Block Torque Limits: Secure all field wiring connections using calibrated hand tools, checking that conductor insulation does not enter the clamp mechanism. Proper torque limits ensure terminal continuity and eliminate resistive heating across high-current relay circuits.