GE WESDAC D20C D20 RTU Combination I/O Board 68HC11
GE WESDAC D20C D20 RTU Combination I/O Board 68HC11
GE WESDAC D20C D20 RTU Combination I/O Board 68HC11
/ 3

GE WESDAC D20C D20 RTU Combination I/O Board 68HC11

  • Manufacturer: GE Fanuc

  • Part Number: WESDAC D20C

  • Condition:New with Original Package

  • Product Type: Substation Automation Modules

  • Country of Origin: USA

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

GE WESDAC D20C D20 Substation Automation I/O Board

The GE WESDAC D20C, also cataloged as the WESDAC D20C Analog Digital I/O Module, operates as a dedicated hardware component for distributed signal acquisition and local logic execution within GE D20 and D200 Remote Terminal Unit (RTU) platforms. The module consists of a WESTERM D20C field termination board and a WESDAC D20C processing board powered by an 8-bit Freescale 68HC11 MPU. Utilizing dual D.20 Link ports, the unit offloads signal conditioning, noise filtering, and trip/close control execution from the primary D20 CPU.

Hardware Specifications

Parameter Specification
Model WESDAC D20C
Brand GE
Origin USA
Weight 1.542 kg
Dimensions 19 in x 5.25 in x 2.5 in (3U Rack-Mount Form Factor)
Operating Temp -40 to +70 deg C
Power Consumption 20 to 60 VDC (5 W Typical / 11 W Full Load)
Processor & Memory 8-bit Freescale 68HC11 MPU (2 MHz), 24 KB EPROM, 32 KB SRAM, 512 B EEPROM
Digital Inputs 16 discrete inputs (12 to 130 VDC range)
Relay Outputs 8 Form C contacts (3 A max)
Optional Analog I/O 16 inputs (+/- 35 VDC, 14-bit) OR 8 inputs + 8 outputs (4-20 mA, 12-bit)
Electrical Isolation 1500 VAC Field-to-Backplane Isolation
Communication Interfaces Dual Redundant D.20 Link Ports, RS-232 Maintenance Port
Supported Protocols Modbus TCP/IP, SRTP, DNP3

Backplane Bus Communication Velocity and System Determinism

The GE WESDAC D20C module interfaces directly with the GE D20 backplane architecture to ensure rapid data exchange across distributed sub-networks. By executing input scanning and filtering locally, the card manages I/O density scaling efficiently while reducing protocol conversion latencies over the dual D.20 Link ports. Onboard firmware flash compatibility across D20 processor nodes maintains deterministic communications during high-volume event logging and protective tripping operations.

Frequently Asked Questions

Q: How does the two-component design simplify module replacement during live operations?

A: The detachable WESTERM D20C termination board remains permanently connected to the cabinet field wiring, allowing engineers to hot-swap the primary WESDAC D20C processing board without disturbing physical terminal blocks or risk rewiring errors.

Q: What power supply range does the module require, and how is the backplane isolated?

A: The module accepts a wide input power supply range from 20 to 60 VDC and features 1500 VAC galvanic isolation between field-side signal lines and the internal D20 backplane logic circuits.

Q: How do the dual D.20 Link communication ports handle network fault recovery?

A: The dual D.20 Link ports support redundant cabling topologies, enabling immediate, deterministic packet re-routing over the secondary link if a primary communication cable experiences an open circuit or signal degradation.

Field Installation Guidelines

Observe the following field installation practices during cabinet integration and commissioning:

  1. Power Isolation & Verification: Verify that input DC power to the rack chassis is within 20 to 60 VDC before seating the card into the 3U sub-rack enclosure.
  2. Termination Board Mounting: Secure the WESTERM D20C termination base to the mounting frame first, ensuring firm earth ground bonding to maintain 1500 VAC field-to-backplane isolation integrity.
  3. ESD & Module Alignment: Wear a grounded ESD wrist strap, align the processing card with the chassis card guides, and push evenly until the edge connectors engage the backplane. Tighten retaining thumbscrews.
  4. Signal Wiring & Shield Grounding: Strip field conductors to recommended lengths, securing 12 to 130 VDC discrete input and 4-20 mA analog wiring to screw terminals. Terminate all cable shields to the main cabinet ground bus.
  5. Thermal & Clearance Spacing: Maintain a minimum 50 mm clearance above and below the 3U rack assembly to allow unhindered vertical convection, ensuring ambient air remains within the -40 to +70 deg C operating window.