GE WESDAC D20C D20 Substation Automation I/O Board
The GE WESDAC D20C, also cataloged as the WESDAC D20C Analog Digital I/O Module, operates as a dedicated hardware component for distributed signal acquisition and local logic execution within GE D20 and D200 Remote Terminal Unit (RTU) platforms. The module consists of a WESTERM D20C field termination board and a WESDAC D20C processing board powered by an 8-bit Freescale 68HC11 MPU. Utilizing dual D.20 Link ports, the unit offloads signal conditioning, noise filtering, and trip/close control execution from the primary D20 CPU.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | WESDAC D20C |
| Brand | GE |
| Origin | USA |
| Weight | 1.542 kg |
| Dimensions | 19 in x 5.25 in x 2.5 in (3U Rack-Mount Form Factor) |
| Operating Temp | -40 to +70 deg C |
| Power Consumption | 20 to 60 VDC (5 W Typical / 11 W Full Load) |
| Processor & Memory | 8-bit Freescale 68HC11 MPU (2 MHz), 24 KB EPROM, 32 KB SRAM, 512 B EEPROM |
| Digital Inputs | 16 discrete inputs (12 to 130 VDC range) |
| Relay Outputs | 8 Form C contacts (3 A max) |
| Optional Analog I/O | 16 inputs (+/- 35 VDC, 14-bit) OR 8 inputs + 8 outputs (4-20 mA, 12-bit) |
| Electrical Isolation | 1500 VAC Field-to-Backplane Isolation |
| Communication Interfaces | Dual Redundant D.20 Link Ports, RS-232 Maintenance Port |
| Supported Protocols | Modbus TCP/IP, SRTP, DNP3 |
Backplane Bus Communication Velocity and System Determinism
The GE WESDAC D20C module interfaces directly with the GE D20 backplane architecture to ensure rapid data exchange across distributed sub-networks. By executing input scanning and filtering locally, the card manages I/O density scaling efficiently while reducing protocol conversion latencies over the dual D.20 Link ports. Onboard firmware flash compatibility across D20 processor nodes maintains deterministic communications during high-volume event logging and protective tripping operations.
Frequently Asked Questions
Q: How does the two-component design simplify module replacement during live operations?
A: The detachable WESTERM D20C termination board remains permanently connected to the cabinet field wiring, allowing engineers to hot-swap the primary WESDAC D20C processing board without disturbing physical terminal blocks or risk rewiring errors.
Q: What power supply range does the module require, and how is the backplane isolated?
A: The module accepts a wide input power supply range from 20 to 60 VDC and features 1500 VAC galvanic isolation between field-side signal lines and the internal D20 backplane logic circuits.
Q: How do the dual D.20 Link communication ports handle network fault recovery?
A: The dual D.20 Link ports support redundant cabling topologies, enabling immediate, deterministic packet re-routing over the secondary link if a primary communication cable experiences an open circuit or signal degradation.
Field Installation Guidelines
Observe the following field installation practices during cabinet integration and commissioning:
- Power Isolation & Verification: Verify that input DC power to the rack chassis is within 20 to 60 VDC before seating the card into the 3U sub-rack enclosure.
- Termination Board Mounting: Secure the WESTERM D20C termination base to the mounting frame first, ensuring firm earth ground bonding to maintain 1500 VAC field-to-backplane isolation integrity.
- ESD & Module Alignment: Wear a grounded ESD wrist strap, align the processing card with the chassis card guides, and push evenly until the edge connectors engage the backplane. Tighten retaining thumbscrews.
- Signal Wiring & Shield Grounding: Strip field conductors to recommended lengths, securing 12 to 130 VDC discrete input and 4-20 mA analog wiring to screw terminals. Terminate all cable shields to the main cabinet ground bus.
- Thermal & Clearance Spacing: Maintain a minimum 50 mm clearance above and below the 3U rack assembly to allow unhindered vertical convection, ensuring ambient air remains within the -40 to +70 deg C operating window.