Governor Actuator Module Engine Control Woodward 8250-828
Manufacturer: Woodward
-
Part Number: 8250-828
Condition:New with Original Package
Product Type:
-
Country of Origin: GERMANY
Payment:T/T, Western Union
Shipping port: Xiamen
Warranty: 12 months
Woodward 8250-828 Governor Actuator Module
The Woodward 8250-828, also cataloged as the 8250-828 Governor Actuator Module, operates as a dedicated hardware component for fuel rack and throttle valve positional execution within turbine and diesel engine governor networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | 8250-828 |
| Brand | Woodward |
| Origin | USA |
| Weight | 3.5 kg |
| Dimensions | 544 x 572 x 322 mm |
| Operating Temp | -40 to +85 deg C |
| Power Consumption | 24 VDC nominal |
| Actuator Motor | Limited Angle Torque (LAT) motor with integral electronics |
| Angular Travel | 75 deg mechanical rotation (typical) |
| Dynamic Isolation | 300 V channel-to-system bus isolation |
| Enclosure Rating | Rugged industrial enclosure, vibration-resistant |
| Certifications | CE, UL, RoHS |
Actuator Loop Feedback Response & Dynamic Response
The integrated Limited Angle Torque (LAT) motor executes rapid rotational adjustments across its 75 deg travel range to optimize the overall actuator loop feedback response during abrupt generator load transients. Internal driver electronics process speed demands directly from connected electronic governors, delivering high rotational torque to overcome valve stiction and mechanical linkage drag. Furthermore, specialized thermal heat sink dissipation profiles integrated within the aluminum housing maintain motor winding integrity and position stability under continuous high-load operations across the entire -40 to +85 deg C thermal envelope.
Frequently Asked Questions
Q: How does the 300 V isolation barrier protect the internal drive electronics? A: The 300 V galvanic isolation isolates internal logic circuitry from external ground potential differences and induced common-mode voltage spikes on long signal cable runs.
Q: What mounting precautions preserve positional accuracy in high-vibration applications? A: Installers must secure the module to a rigid, vibration-damped structural bracket using heavy-duty hardware and maintain proper axial alignment between the actuator output shaft and the engine linkage to prevent radial binding.
Field Installation Guidelines
Mount the unit directly adjacent to the prime mover linkage utilizing all primary mounting points to minimize angular deflection under torque load. Connect the primary supply to a clean, regulated 24 VDC source, verifying that all power leads comply with field wiring current capacity standards. Mechanics must align the output shaft linkage to prevent mechanical deadbands or physical over-travel against hard mechanical stops. Electricians must route control lines in shielded, twisted-pair cables separate from high-current AC lines, grounding the shield at the control cabinet bus bar to block electromagnetic interference.