HIMA ETA8345 30A H7201 Panel Mount Circuit Breaker
HIMA ETA8345 30A H7201 Panel Mount Circuit Breaker
HIMA ETA8345 30A H7201 Panel Mount Circuit Breaker
/ 3

HIMA ETA8345 30A H7201 Panel Mount Circuit Breaker

  • Manufacturer: HIMA

  • Part Number: ETA8345 30A H7201

  • Condition:New with Original Package

  • Product Type: Miniature Circuit Breakers

  • Country of Origin: Germany

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

HIMA ETA8345 30A H7201 Hydraulic-Magnetic Circuit Breaker

The HIMA ETA8345 30A H7201, also cataloged as the ETA8345 Hydraulic-Magnetic Circuit Breaker, operates as a dedicated hardware component for temperature-independent overcurrent protection within HIMA safety system power distribution networks.

Hardware Specifications

Parameter Specification
Model ETA8345 30A H7201
Brand HIMA
Origin Germany
Component Type Hydraulic-Magnetic Circuit Breaker
Rated Current 30 A
Voltage Rating Up to 240 VDC / 277-480 VAC
Trip Mechanism Hydraulic-magnetic, trip-free toggle
Mounting Style Panel Mount
Pole Configuration Single or Double Pole
Weight 0.3 kg
Dimensions 12 cm x 18 cm x 14.4 cm
Operating Temp -40 deg C to +85 deg C
Power Consumption Passive Component (Internal coil sensing resistance)
Certifications CE, FCC

Functional Safety & Galvanic Isolation Attributes

The unit provides rapid overcurrent disconnect capabilities to support fail-safe state execution in high-availability SIL3 control power networks. The hydraulic-magnetic sensing mechanism avoids thermal ambient ambient derating, maintaining strict tripping precision across wide operating ranges. Physical contact separation guarantees total galvanic isolation during fault conditions, protecting upstream logic subracks and downstream field devices against short-circuit damage and power distribution faults.

Frequently Asked Questions

Q: How does the hydraulic-magnetic trip mechanism differ from thermal-magnetic circuit breakers?

A: Hydraulic-magnetic sensing relies on magnetic flux generated by current flow rather than bimetallic heating, preventing ambient temperature fluctuations from altering the 30 A trip threshold.

Q: What safety protection does the trip-free toggle mechanism provide during an active fault?

A: The internal latch mechanism overrides manual operator force, causing contacts to open immediately during overcurrent conditions even if the external toggle switch is held in the ON position.

Field Installation Guidelines

Follow these technical procedures during panel installation and electrical integration:

  1. Verify that incoming supply voltages do not exceed the max rated limits of 240 VDC or 480 VAC prior to wiring.
  2. Mount the breaker chassis directly onto the panel layout cutout using designated mounting hardware to ensure physical stability against vibration.
  3. Connect power conductors using correctly sized ring terminals or ferrules rated for 30 A continuous duty.
  4. Torque terminal screws to manufacturer specifications to prevent high-resistance contact points and excessive localized heat accumulation.
  5. Maintain clear mechanical clearance around the front toggle switch to allow unhindered trip action during fault conditions.