{"product_id":"hima-z-7138-z7138-hiquad-cable-plug-module","title":"HIMA Z 7138 Z7138 HIQuad Cable Plug Module","description":"\u003ch2\u003eHIMA Z 7138 Cable Plug\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHIMA Z 7138\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eZ7138\u003c\/strong\u003e Cable Plug, operates as a dedicated hardware component for safe field signal interconnectivity and digital output loop execution within HIMA HIQuad and HIMatrix safety systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eZ7138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.66 kg (1.46 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e20 x 10 x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 80 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e100 mA (module only, excluding load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 independent digital outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (20.4 to 31.2 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e500 mA per channel (resistive\/inductive loads)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd\u003eSIL 3 (IEC 61508), PL e (EN ISO 13849 Cat. 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Specifications\u003c\/td\u003e\n\u003ctd\u003ePre-wired 5 meter cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP67 (cable plug)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSIL3 Certification and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe cable plug assembly integrates with the HIMA safety backplane to ensure deterministic signal delivery across critical safety loops. Certified up to SIL 3 and PL e levels, the module hardware guarantees immediate fail-safe state execution upon detecting loop disruption or internal system faults. Advanced internal galvanic isolation and continuous onboard diagnostics prevent fault propagation across channels, protecting output stages during emergency shutdown events.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the module react when an output channel encounters a field wiring fault?\u003c\/p\u003e\n\u003cp\u003eA: Integrated self-diagnostics detect open circuits, short circuits, and supply under-voltage conditions, automatically driving the affected channel into a fail-safe state.\u003c\/p\u003e\n\u003cp\u003eQ: What ingress protection rating does the Z 7138 cable plug sub-assembly carry?\u003c\/p\u003e\n\u003cp\u003eA: The pre-wired cable plug interface features an IP67 protection rating, shielding the multi-pin connector contacts against water immersion and dust ingress in harsh environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eObserve strict safety installation procedures to ensure SIL 3 compliance:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eAlign the Z 7138 plug keyway carefully with the module header connector and secure the retaining screws to guarantee a sealed IP67 connection.\u003c\/li\u003e\n\u003cli\u003eMaintain clean signal wire routing by isolating the 5 meter pre-wired cable from high-voltage AC lines or variable frequency drive cables.\u003c\/li\u003e\n\u003cli\u003eVerify local panel earthing by bonding the cable shield directly to the central enclosure earth bus using a low-impedance grounding clamp.\u003c\/li\u003e\n\u003cli\u003eEnsure connected inductive field loads (such as solenoid valves) do not exceed the 500 mA output current rating per channel.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":42923880415331,"sku":"Z 7138","price":110.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/487_773114bc-360b-4d45-a366-d93112930499.jpg?v=1786351224","url":"https:\/\/www.autocontrolglobal.com\/products\/hima-z-7138-z7138-hiquad-cable-plug-module","provider":"AutoControl Global","version":"1.0","type":"link"}