{"product_id":"honeywell-10106-2-1-fsc-line-monitored-digital-input-modules","title":"Honeywell 10106\/2\/1 FSC Line-Monitored Digital Input Modules","description":"\u003ch2\u003eHoneywell 10106\/2\/1 FSC Line-Monitored Digital Input Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for discrete signal acquisition in Fail Safe Control networks, the \u003cstrong\u003eHoneywell 10106\/2\/1\u003c\/strong\u003e (\u003cstrong\u003e10106\/2\/1\u003c\/strong\u003e Line-Monitored Digital Input Module) provides direct physical and electrical execution by monitoring sixteen independent NAMUR-compatible field channels.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e10106\/2\/1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.2 to 1.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e4 TE x 3 HE (4 HP, 3U eurocard format)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial operating range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC at 160 mA; 24 VDC at 110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Input Channels\u003c\/td\u003e\n\u003ctd\u003e16 NAMUR-compliant digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitch Level \/ Hysteresis\u003c\/td\u003e\n\u003ctd\u003e1.4 to 1.9 mA \/ 0.2 mA (+\/-0.05 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoop Supply Output\u003c\/td\u003e\n\u003ctd\u003e7.9 to 8.7 V (170 mA short-circuit proof)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Field Wire Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Process Control\u003c\/h3\u003e\n\u003cp\u003eThe module processes sixteen active sensor loops while enforcing rigorous channel-to-channel isolation to prevent loop cross-interference across safety-related networks. Internal circuitry monitors incoming current thresholds according to DIN 19234 standards, while cold junction compensation and digital filtering algorithms stabilize signal interpretation under heavy electrical noise. Furthermore, integrated diagnostic routines evaluate field wiring continuity, detecting open and short-circuit faults across each connected loop during continuous system execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the current threshold switching levels for the NAMUR input channels?\u003c\/p\u003e\n\u003cp\u003eA: The input channels switch between valid states within a range of 1.4 to 1.9 mA, utilizing a hysteresis of 0.2 mA (+\/-0.05 mA).\u003c\/p\u003e\n\u003cp\u003eQ: What power supply loads does the module draw during active operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit consumes 160 mA from the 5 VDC backplane rail and 110 mA from the 24 VDC system rail.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module supply power to external field sensors?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the integrated loop supply provides an output voltage between 7.9 and 8.7 V with a short-circuit proof current limit of 170 mA.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure system rack power is completely de-energized before handling the hardware. Align the printed circuit board edges of the 10106\/2\/1 module with the designated 4 TE wide guide slots inside the Honeywell FSC chassis. Slide the unit firmly into the backplane until the rear interface connector seats securely. Fasten the top and bottom front panel mounting screws to establish proper chassis ground continuity and secure mechanical retention before applying system power.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43120954769507,"sku":"10106\/2\/1","price":253.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/1010621_1.jpg?v=1741069240","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-10106-2-1-fsc-line-monitored-digital-input-modules","provider":"AutoControl Global","version":"1.0","type":"link"}