{"product_id":"honeywell-12-sbus-rack-mounted-automation-module-chassis","title":"Honeywell 12-SBUS Rack-Mounted Automation Module Chassis","description":"\u003ch2\u003eHoneywell 12-SBUS Rack Chassis\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 12-SBUS\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e12-SBUS\u003c\/strong\u003e Rack Chassis, operates as a dedicated hardware component for high-density modular mounting within industrial automation network architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e12-SBUS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e15.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e580 x 450 x 240 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Mechanical Chassis)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e12 SBUS modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e12-SBUS\u003c\/strong\u003e chassis provides the physical backplane interface necessary for hosting Honeywell SBUS-compatible automation components. This housing facilitates the transmission of 4-20 mA HART loop protocol data by providing a structurally stable and electromagnetically shielded environment for the underlying electronics. To maintain signal integrity, the chassis utilizes an integrated grounding scheme that supports channel-to-channel isolation requirements across the installed module set. The passive airflow design ensures that thermal dissipation remains within safe limits for all hosted units, effectively mitigating the risk of localized overheating that could otherwise degrade precision measurement components or impact cold junction compensation (CJC) accuracy in analog input modules.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 12-SBUS chassis require active cooling?\u003c\/p\u003e\n\u003cp\u003eA: No, the chassis utilizes a passive airflow design. Ensure that the rack ventilation system allows for adequate air circulation through the chassis vents to maintain internal module temperatures.\u003c\/p\u003e\n\u003cp\u003eQ: Is the chassis compatible with mixed-module configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 12-SBUS supports the installation of up to 12 modules in any combination, provided they adhere to the standard SBUS form factor and backplane connector specifications.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Secure the chassis into a standard 19-inch equipment rack using the four heavy-duty rack-ear mounting holes. Ensure that the chassis frame maintains a low-impedance bond to the rack's primary earth ground to minimize the potential for common-mode noise injection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Route signal cables through the integrated cable management paths. Keep control signal wiring separated from high-voltage power lines to prevent electromagnetic interference (EMI) on the field loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Align the SBUS module with the chassis guide slots and verify that the backplane connector is fully seated. Tighten any integrated retention screws to secure the module against vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify the integrity of the chassis-to-rack ground bond using a low-resistance ohmmeter. Ensure all shields are properly terminated at the rack's common signal ground to mitigate circulating currents.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43853900021859,"sku":"12-SBUS","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/278_492f39b4-9013-42b4-8fed-0e397f56c9a3.jpg?v=1764058824","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-12-sbus-rack-mounted-automation-module-chassis","provider":"AutoControl Global","version":"1.0","type":"link"}