{"product_id":"honeywell-51153818-203-tdc3000-jumper-interconnection-kits","title":"Honeywell 51153818-203 TDC3000 Jumper Interconnection Kits","description":"\u003ch2\u003eHoneywell 51153818-203 TPS\/TDC Series\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 51153818-203\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eHoneywell 51153818\u003c\/strong\u003e Jumper Interconnection Kit, operates as a dedicated hardware component for localized routing of low-voltage bus signals within TPS, TDC2000, and TDC3000 Distributed Control Systems. The hardware establishes physical electrical continuity across adjacent backplane pins to patch distinct I\/O nodes without structural alterations to the core system backplane architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51153818-203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.56 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3 x 31.3 x 27.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e0 W (Passive electrical component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eJumper Kit (I\/O Interconnection Accessory)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumper Quantity\u003c\/td\u003e\n\u003ctd\u003e21-30 wire jumpers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJumper Pitch\u003c\/td\u003e\n\u003ctd\u003e2.54 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade conductor wire and termination connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003eStandard system bus voltage (low-voltage signal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL508, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDistributed Control System Loop Integration\u003c\/h3\u003e\n\u003cp\u003eThe hardware interconnect matrix routes low-voltage analog and digital instrumentation signals across backplane segments before they enter the distributed control system (DCS) processing layer. By establishing direct conductive mapping across a 2.54 mm pitch layout, this assembly facilitates unattenuated pass-through for 4-20 mA HART loop protocol variables and high-speed system bus communications. The solid wire properties preserve the signal-to-noise ratio required by high-density analog modules, maintaining channel integrity against cross-talk without altering pre-existing channel-to-channel isolation barriers on the primary I\/O board.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the physical spacing layout of the individual pins within this interconnection module? A: The kit utilizes a standard jumper pitch of 2.54 mm, ensuring mechanical compatibility with the pin grids found on legacy TDC and modern TPS backplane components.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 51153818-203 kit require external electrical excitation or software configuration? A: No, the hardware consists of passive conductor wires and connectors that operate solely on the system bus low-voltage signal layer, requiring zero power draw and no software mapping.\u003c\/p\u003e\n\u003cp\u003eQ: Can this jumper assembly handle high-voltage alternating current (VAC) power circuits? A: No, the design parameters restrict usage strictly to low-voltage system bus signaling and logic-level interconnection points.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify that the primary distributed control system chassis is powered down before introducing or removing any wire jumpers from the backplane connectors.\u003c\/li\u003e\n\u003cli\u003eAlign the 2.54 mm pitch connector blocks perfectly with the target pin header rows on the TPS\/TDC backplane to avoid bending or shorting adjacent pins.\u003c\/li\u003e\n\u003cli\u003eRoute the integrated wire bundles away from active high-voltage lines or inductive switching components inside the enclosure to mitigate electromagnetic coupling risks.\u003c\/li\u003e\n\u003cli\u003eEnsure the physical locking features of the connectors are fully seated to withstand mechanical vibrations and maintain continuous circuit contact within industrial panels.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43869106995299,"sku":"51153818-203","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/399_402a794b-e474-4ab4-b7c7-1f345fb7220c.jpg?v=1764748774","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-51153818-203-tdc3000-jumper-interconnection-kits","provider":"AutoControl Global","version":"1.0","type":"link"}