{"product_id":"honeywell-51405047-176-control-firewall-fte-distribution","title":"Honeywell 51405047-176 Control Firewall FTE Distribution","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PCF901 (Part Number: 51405047-176)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a specialized Control Firewall Module designed for the Series C hardware platform within the Experion PKS ecosystem. This module manages the distribution of Fault Tolerant Ethernet (FTE) signals to multiple in-cabinet network nodes, including C300 Controllers and Field Interface Modules (FIMs). By providing 8 dedicated ports plus 1 uplink, it secures and optimizes data traffic between the supervisory network and the controller level. We offer this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum network security and uptime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CC-PCF901 provides high-speed switching and robust environmental protection for mission-critical control networks.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePort Configuration\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Downlink Ports + 1 Uplink Port\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNetwork Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFault Tolerant Ethernet (FTE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e112mA to 195mA (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eEnvironmental Protection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG3 Conformal Coating (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMounts on CF9 I\/O Termination Assembly (IOTA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 cm x 13.5 cm x 23.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, ATEX, IECEx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSecured FTE Distribution:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe CC-PCF901 isolates the control network from the broader plant network. It prevents broadcast storms and unauthorized traffic from disrupting the C300 controller's communication with its I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Cabinet Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module eliminates the need for bulky third-party commercial switches. It mounts directly onto the Series C CF9 IOTA, reducing wiring clutter and saving valuable DIN rail space.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eG3 Conformal Coating:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHoneywell applies G3-level coating to the CC-PCF901 by default. This high-grade protection resists corrosion caused by airborne contaminants, making it suitable for deployment in harsh refinery or chemical plant environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Network Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module facilitates the redundant architecture of Experion PKS. It ensures that if one FTE cable fails, the control firewall maintains the data path through the secondary port without losing process visibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Hot-Swapping:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers can replace the firewall module under live power. Because the configuration resides in the system, the new module automatically resumes traffic management upon insertion, preventing process interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the difference between the 8 ports and the uplink port on the CC-PCF901?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 8 downlink ports provide FTE connectivity to in-cabinet nodes like C300 controllers and Series C I\/O modules. The 1 uplink port connects the entire cabinet sub-network to the primary FTE branches of the Experion PKS network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Does this module require manual software configuration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The CC-PCF901 functions as a managed industrial switch optimized for FTE. Once installed on the CF9 IOTA and connected to the network, it handles traffic distribution according to the Experion PKS system architecture without requiring per-port manual IP setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Why is the \"G3\" rating significant for this firewall module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe G3 rating refers to the ISA-S71.04 standard for corrosive environments. It means the 51405047-176 can withstand high concentrations of H2S, SO2, and Cl2, which would typically cause standard electronics to fail within months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Is the CF9 IOTA included with the CC-PCF901?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. The 51405047-176 is the plug-in electronic module only. The CF9 IOTA (Input\/Output Termination Assembly) must be purchased separately or be already present in the cabinet for installation.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44142773928035,"sku":"CC-PCF091 51405047-176","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/366._5e74b875-780d-4143-b42c-965f9a57f5fb.jpg?v=1777252756","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-51405047-176-control-firewall-fte-distribution","provider":"AutoControl Global","version":"1.0","type":"link"}