{"product_id":"honeywell-51454205-175-uio-module-experion-pks-original","title":"Honeywell 51454205-175 UIO Module Experion PKS Original","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell CC-PUIO01 (Part Number: 51454205-175)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003erepresents the next generation of software-defined hardware for the Experion PKS Series C system. This\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eUniversal Input\/Output (UIO) module\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efeatures 32 individually configurable channels, allowing each port to function as an Analog Input, Analog Output, Digital Input, or Digital Output. By consolidating four distinct I\/O types into a single card, the CC-PUIO01 eliminates the need for specialized hardware inventory and simplifies complex project engineering. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure maximum flexibility for your control system architecture.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe CC-PUIO01 provides high-density signal processing and integrated digital communication within a standard Series C form factor.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eChannel Count\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 Channels (Individually Configurable)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Types\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI (4-20mA), AO (4-20mA), DI (24VDC), DO (24VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDigital Protocol\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated HART Pass-through (on Analog channels)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHoneywell Experion PKS Series C, C300 Controllers\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Regulated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStorage Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–40°C to +85°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5%–95% RH (Non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHot-swappable into Series C \/ Series 8 Chassis\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, ATEX, IECEx\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Defined Versatility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineers configure each channel type via the Experion Configuration Studio. This capability allows for late-stage design changes without the cost of rewiring or purchasing new hardware modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Spare Parts Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause the CC-PUIO01 handles any signal type, plants can reduce their spare part inventory significantly. One UIO module replaces the need to stock separate AI, AO, DI, and DO cards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated HART Intelligence:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module supports HART pass-through for all analog-configured channels. This enables the retrieval of secondary variables and deep device diagnostics from smart field instruments directly into the Experion environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Engineering \u0026amp; FEED:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe universal nature of the 51454205-175 reduces Front-End Engineering Design (FEED) errors. You no longer need to finalize specific I\/O counts before ordering hardware, which accelerates commissioning timelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Fault Detection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module monitors each of the 32 channels for open circuits and short circuits in real-time. It provides immediate feedback to the operator station, allowing for rapid troubleshooting of field-side wiring issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial-Grade Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for mission-critical environments, the module features a wide operating temperature range and protective coating, ensuring stable operation from –40°C to +70°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. How do I change a channel from Digital Input to Analog Output?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYou perform all channel assignments through the Honeywell Experion Configuration Studio software. Once you update the configuration and download it to the controller, the CC-PUIO01 internally reassigns the electronic circuitry for that specific channel without requiring physical jumpers or wiring changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Does the CC-PUIO01 support redundancy for high-availability loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The module supports redundant operation when installed in a redundant Series C\/Series 8 chassis. The system facilitates a bumpless switchover between primary and secondary modules to ensure continuous process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Is there a limitation on how many HART devices I can connect?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach of the 32 channels supports HART communication if configured as an Analog signal type. This allows you to integrate a high density of smart field devices into a single I\/O footprint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. Can this module be used as a Power Interface Unit (PIU)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile some documentation groups Universal I\/O with power distribution roles in the chassis, the CC-PUIO01 primarily functions as a signal interface. It receives regulated 24VDC power from the chassis backplane and distributes it to the field devices according to the configured channel type.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44142800470115,"sku":"CC-PUI001 51454205-175","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/374.1_b52f92ec-b0f4-498e-b15e-0accca78f709.jpg?v=1777253496","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-51454205-175-uio-module-experion-pks-original","provider":"AutoControl Global","version":"1.0","type":"link"}