{"product_id":"honeywell-51454471-175-safety-analog-output-4-20ma-card","title":"Honeywell 51454471-175 Safety Analog Output 4-20mA Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-SAO-0220M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity Safety Analog Output (SAO) module within the Honeywell Safety Manager and Experion PKS ecosystems. This module provides two independent, safe analog current channels (4–20 mA) designed to drive final control elements such as valve positioners, dampers, and I\/P converters. Engineered for Safety Instrumented Systems (SIS), the FC-SAO-0220M ensures that critical actuators reach their fail-safe positions during emergency shutdown (ESD) events. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto guarantee compliance with your plant's SIL3 safety requirements.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe FC-SAO-0220M combines high-precision D\/A conversion with continuous hardware monitoring for safety-critical loops.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Independent Safety Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSignal Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–20 mA (Standard)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 to 16-bit (Configuration Dependent)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.1% Full Scale (Typical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eLoad Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 750 Ω\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSafety Certification\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV SIL3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Power\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eChannel-to-Channel and Channel-to-System\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail TS32 \/ TS35 × 7.5\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 °C to +60 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 KG\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertified SIL3 Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module holds TÜV SIL3 certification, making it a primary choice for high-stakes safety applications where hardware failure could lead to catastrophic events. It manages critical valve positioning in Oil \u0026amp; Gas, Chemical, and Power sectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRedundant Interfacing Capability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-SAO-0220M connects to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSAOH-0220M Field Termination Assembly\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003evia the SICC-0001\/Lx interconnection cable. This architecture supports redundant SAO-0220M module pairs, ensuring that if one module fails, the secondary unit maintains the control signal without interruption.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Diagnostic Coverage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module constantly monitors output integrity. It detects open wire conditions, short circuits, and internal D\/A converter faults. If a discrepancy occurs, the system immediately alerts the operator and initiates the programmed safe-state protocol.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGalvanic Electrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust isolation between channels and the system bus prevents electrical noise or field-side surges from propagating back into the central safety controller. This ensures signal purity and protects expensive system hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRugged Industrial Build:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating protects the internal circuitry from moisture and corrosive gases common in petrochemical plants. The module maintains stable ±0.1% accuracy across its full operating temperature range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSimplified Field Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes standard screw terminals on the associated FTA, accommodating wires up to 2.5 mm² (AWG 14). This standardized termination simplifies the transition from the control room to the field devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. How do I configure a redundant pair with the FC-SAO-0220M?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTo achieve redundancy, you must install two FC-SAO-0220M modules on a redundant-capable backplane and connect them to the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eTSAOH-0220M Field Termination Assembly\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eusing the SICC-0001\/Lx system interconnection cable. The Safety Manager software then manages the bumpless switchover between the primary and secondary modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Can this module drive high-impedance loads?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FC-SAO-0220M supports load capacities up to 750 Ω. This accommodates long cable runs between the control cabinet and the field device, which is common in large-scale industrial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Does the module support HART communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FC-SAO-0220M focuses on the high-integrity delivery of the 4–20 mA safety signal. For applications requiring bi-directional HART diagnostics, verify that your field instruments and the specific Safety Manager hardware revision support HART pass-through via the SICC cable architecture.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e4. What is the difference between the SAO and TSAO designations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-SAO-0220M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis the electronic Safety Analog Output module that processes the logic. The\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFC-TSAO-0220M\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(or TSAOH-0220M) is the Field Termination Assembly—the passive physical board where you terminate your field wires and connect the module via a system cable.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44142899953763,"sku":"FC-SAO-0220M","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/105._6a920caf-7ce6-46f8-a264-9ea3321d3c72.jpg?v=1777257597","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-51454471-175-safety-analog-output-4-20ma-card","provider":"AutoControl Global","version":"1.0","type":"link"}