{"product_id":"honeywell-8-channel-safe-digital-output-module-fc-sdo-0824","title":"Honeywell 8-Channel Safe Digital Output Module FC-SDO-0824","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eHoneywell FC-SDO-0824\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-integrity Safe Digital Output Module for the Honeywell Safety Manager and PLC architectures. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e8 discrete output channels\u003c\/strong\u003e, specifically designed to drive 24VDC field loads such as solenoids, interposing relays, and audible alarms. Each channel delivers up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.55A\u003c\/strong\u003e, providing the necessary power for critical final control elements in safety-instrumented functions (SIF). We supply this module as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your safety loops maintain maximum availability and compliance with global safety standards.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFC-SDO-0824\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafe Digital Output Module (SDO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOutput Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Discrete Isolated Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Current per Channel\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic isolation (Logic to Field and Channel-to-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIndividual LED status per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e–20°C to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN Rail or Panel Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg (0.3 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA Certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eComprehensive Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FC-SDO-0824 employs strict galvanic isolation between the internal logic circuits and the field-side outputs. This architecture prevents field-side electrical surges or ground loops from damaging the central safety processor, ensuring high system uptime.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach output channel integrates a dedicated LED indicator for real-time visual status verification. This hardware-level feedback allows maintenance teams to identify failed solenoids or wiring open-circuits instantly, reducing Mean Time to Repair (MTTR) in critical process environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Integrity Switching:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for Safety Manager integration, the module manages inrush currents up to 0.55A per channel. It effectively controls low-power actuators and safety relays without the need for additional external interposing hardware in many standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact Industrial Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe lightweight, industrial-grade composite housing optimizes cabinet space. Its dual mounting capability (DIN rail or panel) provides engineers with flexible installation options in both centralized control rooms and decentralized remote instrument enclosures (RIE).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FC-SDO-0824 suitable for SIL3 safety loops?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. When integrated within a certified Honeywell Safety Manager system and configured according to the Safety Manual, the FC-SDO-0824 supports loops requiring high safety integrity levels (SIL).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this module drive inductive loads like large solenoid valves?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module handles loads up to 0.55A. For high-inductive loads or currents exceeding 0.55A, we recommend using an interposing relay to protect the module’s internal switching components and extend the service life of the hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module require a separate power supply for the field side?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module typically requires a 24VDC field power source to drive the output loads. The internal galvanic isolation keeps this field power separate from the 3500-style backplane or logic power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the lead time for this original Honeywell stock?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe maintain\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New, Original stock\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor the FC-SDO-0824. Depending on your location and order volume, we typically ship via DHL or FedEx with delivery windows ranging from 3 to 14 days.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":43797472313443,"sku":"SF-SDO-0824","price":320.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/599.jpg?v=1761699103","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-8-channel-safe-digital-output-module-fc-sdo-0824","provider":"AutoControl Global","version":"1.0","type":"link"}