{"product_id":"honeywell-8c-taixa1-experion-pks-series-8-analog-input-modules","title":"Honeywell 8C-TAIXA1 Experion PKS Series 8 Analog Input Modules","description":"\u003ch2\u003eHoneywell 8C-TAIXA1 Experion PKS Series 8 Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 8C-TAIXA1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8C-TAIXA1\u003c\/strong\u003e Analog Input Module, serves as the primary \u003cstrong\u003e8C-TAIXA1\u003c\/strong\u003e Analog Input Module utilized to execute high-precision process signal acquisition across Experion PKS platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8C-TAIXA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e11.8 x 13.1 x 6.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e105-110 mA @ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 single-ended channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003e4-20 mA current, 0-10 VDC, +\/-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Resolution\u003c\/td\u003e\n\u003ctd\u003e16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms channel-to-backplane galvanic isolation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Protection\u003c\/td\u003e\n\u003ctd\u003eOver-voltage, over-current, reverse polarity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 8C-TAIXA1 module integrates with field instrumentation loops using 4-20 mA analog signals to ensure constant transmission verification. The internal hardware architecture incorporates 2500 Vrms galvanic isolation to separate the field side terminals from the backplane logic bus. This barrier mitigates cross-talk propagation and counteracts ground potential variations across adjacent measurement lines. Built-in noise rejection filters attenuate 50\/60 Hz line-frequency interference, maintaining a common-mode rejection ratio (CMRR) greater than 120 dB during high-density signal scanning loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the system manage 1:1 hardware redundancy during a component anomaly?\u003c\/p\u003e\n\u003cp\u003eA: The module operates alongside a paired redundant block to execute continuous state synchronization. If the primary module fails internal diagnostic checks, the system switches to the backup device within the specified 50 ms loop cycle without disrupting active data acquisition.\u003c\/p\u003e\n\u003cp\u003eQ: What are the specific environmental limitations concerning hot-swap operations?\u003c\/p\u003e\n\u003cp\u003eA: This module supports full online hot-swap capabilities inside standard IP20 cabinet installations. Technicians can extract and replace a faulted unit while the backplane remains energized, provided the ambient humidity falls within the 0-95% non-condensing operating boundary.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlign the module with the designated Series 8 I\/O rack slot guides and insert it firmly until the physical locking pins engage with the assembly.\u003c\/li\u003e\n\u003cli\u003eConfirm that the external 24 VDC power supply connection complies with the electrical consumption thresholds specified on the module sub-assembly plate.\u003c\/li\u003e\n\u003cli\u003eConnect all field input cables to the matching Input Output Termination Assembly (IOTA), keeping signal wires separate from high-voltage AC cables inside the cabinet tracking.\u003c\/li\u003e\n\u003cli\u003eVerify that the local cabinet grounding bar links directly to the master instrumentation earth to maintain the effectiveness of the 2500 Vrms isolation barrier.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":44282240139363,"sku":"8C-TAIXB1","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/564._b4381dc5-1619-4531-a92a-1394bac35332.jpg?v=1782206580","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-8c-taixa1-experion-pks-series-8-analog-input-modules","provider":"AutoControl Global","version":"1.0","type":"link"}