Honeywell CC-MCAR01 51403892-100 Experion PKS Carrier Channel Assembly
Honeywell CC-MCAR01 51403892-100 Experion PKS Carrier Channel Assembly
Honeywell CC-MCAR01 51403892-100 Experion PKS Carrier Channel Assembly
/ 3

Honeywell CC-MCAR01 51403892-100 Experion PKS Carrier Channel Assembly

  • Manufacturer: HONEYWELL

  • Part Number: 51403892-100

  • Condition:New with Original Package

  • Product Type: Carrier Channel Assemblies

  • Country of Origin: Sweden

  • Payment:T/T, Western Union

  • Shipping port: Xiamen

  • Warranty: 12 months

Honeywell CC-MCAR01 Carrier Channel Assembly

Configured for interfacing ISA100 wireless field devices in Honeywell Experion PKS platforms, the Honeywell CC-MCAR01, also cataloged as the Honeywell 51403892-100 Carrier Channel Assembly, provides direct physical/electrical execution. The hardware operates as the primary communication link and power distribution infrastructure between wireless field instruments and the C300 controller. The unit passes power across multiple cabinet sides and provides integrated status diagnostics through physical LED indicators.

Hardware Specifications

Parameter Specification
Model CC-MCAR01
Part Number 51403892-100
Brand Honeywell
Origin USA
Type Carrier Channel Assembly
Function ISA100 wireless field device to C300 controller interface
Voltage Range 240-600 VAC / VDC
Current Rating 18 mA
Power Distribution +24 VDC across cabinet sides
Dimensions 270 x 201 x 150 mm
Weight 4.8 kg
Operating Temp -5 to +95 deg C
Certifications CE, UL, CSA, TUV

Process Control and DCS Interface Architecture

The hardware incorporates a dedicated 4-20 mA HART loop protocol layer alongside native digital communication mapping to bridge wireless industrial networks with the Experion PKS C300 control processor. The physical plane utilizes channel-to-channel isolation to prevent transient high-voltage excursions from propagating into the low-voltage backplane logic. Thermal management circuits maintain signaling precision by neutralizing environmental variance, while internal circuitry provides galvanic isolation between the 240-600 VAC/VDC main distribution lines and the secondary +24 VDC sub-buses.

Frequently Asked Questions

Q: What is the mechanical limitation for routing power across adjacent cabinet enclosures?

A: The module internal bus bars distribute +24 VDC directly through standard backplane interconnections, eliminating external jumper wires between consecutive cabinet sections while maintaining a maximum current draw within the 18 mA rated specification.

Q: How does the unit handle dual AC and DC voltage inputs on the same channel?

A: The internal isolation barriers segment incoming voltage fields. The module accepts either AC or DC source power between 240 V and 600 V according to physical terminal configuration, preventing cross-conduction through internal hardware separation.

Q: What diagnostic states do the physical LEDs communicate?

A: The LEDs provide real-time hardware status, indicating the presence of proper +24 VDC distribution across the carrier chassis and the active data communication link status between the ISA100 field devices and the C300 controller interface.

Field Installation Guidelines

  • Mounting Orientation and Clearance: Secure the chassis onto designated cabinet mounting points using standard industrial fasteners. Maintain a minimum clearance of 50 mm on all sides to allow convective thermal dissipation when operating near the upper limit of 95 deg C.
  • Grounding Protocols: Connect the primary grounding lug directly to the low-impedance master cabinet earth ground bus. Ensure the ground strap exhibits a resistance value below 1 Ohm to prevent common-mode noise accumulation on the C300 signal paths.
  • Wiring Separation: Route high-voltage power lines (240-600 VAC/VDC) through separate physical conduits isolated from the low-voltage +24 VDC power distribution and data signaling wires to suppress cross-talk and electromagnetic interference.
  • Terminal Engagement: Terminate all electrical connections using calibrated torque tools to meet manufacturer tension standards. Verify that all field wiring strain reliefs are secured to avoid mechanical loading on the terminal blocks.
You may also like