{"product_id":"honeywell-cc-mcar01-51403892-100-experion-pks-carrier-channel-assembly","title":"Honeywell CC-MCAR01 51403892-100 Experion PKS Carrier Channel Assembly","description":"\u003ch2\u003eHoneywell CC-MCAR01 Carrier Channel Assembly\u003c\/h2\u003e\n\u003cp\u003eConfigured for interfacing ISA100 wireless field devices in Honeywell Experion PKS platforms, the \u003cstrong\u003eHoneywell CC-MCAR01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eHoneywell 51403892-100\u003c\/strong\u003e Carrier Channel Assembly, provides direct physical\/electrical execution. The hardware operates as the primary communication link and power distribution infrastructure between wireless field instruments and the C300 controller. The unit passes power across multiple cabinet sides and provides integrated status diagnostics through physical LED indicators.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCC-MCAR01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e51403892-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eCarrier Channel Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eISA100 wireless field device to C300 controller interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e240-600 VAC \/ VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e18 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Distribution\u003c\/td\u003e\n\u003ctd\u003e+24 VDC across cabinet sides\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e270 x 201 x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-5 to +95 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, TUV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Interface Architecture\u003c\/h3\u003e\n\u003cp\u003eThe hardware incorporates a dedicated 4-20 mA HART loop protocol layer alongside native digital communication mapping to bridge wireless industrial networks with the Experion PKS C300 control processor. The physical plane utilizes channel-to-channel isolation to prevent transient high-voltage excursions from propagating into the low-voltage backplane logic. Thermal management circuits maintain signaling precision by neutralizing environmental variance, while internal circuitry provides galvanic isolation between the 240-600 VAC\/VDC main distribution lines and the secondary +24 VDC sub-buses.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the mechanical limitation for routing power across adjacent cabinet enclosures?\u003c\/p\u003e\n\u003cp\u003eA: The module internal bus bars distribute +24 VDC directly through standard backplane interconnections, eliminating external jumper wires between consecutive cabinet sections while maintaining a maximum current draw within the 18 mA rated specification.\u003c\/p\u003e\n\u003cp\u003eQ: How does the unit handle dual AC and DC voltage inputs on the same channel?\u003c\/p\u003e\n\u003cp\u003eA: The internal isolation barriers segment incoming voltage fields. The module accepts either AC or DC source power between 240 V and 600 V according to physical terminal configuration, preventing cross-conduction through internal hardware separation.\u003c\/p\u003e\n\u003cp\u003eQ: What diagnostic states do the physical LEDs communicate?\u003c\/p\u003e\n\u003cp\u003eA: The LEDs provide real-time hardware status, indicating the presence of proper +24 VDC distribution across the carrier chassis and the active data communication link status between the ISA100 field devices and the C300 controller interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Orientation and Clearance\u003c\/strong\u003e: Secure the chassis onto designated cabinet mounting points using standard industrial fasteners. Maintain a minimum clearance of 50 mm on all sides to allow convective thermal dissipation when operating near the upper limit of 95 deg C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocols\u003c\/strong\u003e: Connect the primary grounding lug directly to the low-impedance master cabinet earth ground bus. Ensure the ground strap exhibits a resistance value below 1 Ohm to prevent common-mode noise accumulation on the C300 signal paths.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Separation\u003c\/strong\u003e: Route high-voltage power lines (240-600 VAC\/VDC) through separate physical conduits isolated from the low-voltage +24 VDC power distribution and data signaling wires to suppress cross-talk and electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Engagement\u003c\/strong\u003e: Terminate all electrical connections using calibrated torque tools to meet manufacturer tension standards. Verify that all field wiring strain reliefs are secured to avoid mechanical loading on the terminal blocks.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":43866246283363,"sku":"51403892-100","price":676.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0583\/5246\/8067\/files\/318.1_26949135-de28-472f-8df1-943e2abdb622.jpg?v=1764644234","url":"https:\/\/www.autocontrolglobal.com\/products\/honeywell-cc-mcar01-51403892-100-experion-pks-carrier-channel-assembly","provider":"AutoControl Global","version":"1.0","type":"link"}